TABLE A4 - Control Board Connector Descriptions (Right Side)

Signal
Description
DI_1
Digital Input1
DI_0
Digital Input0
PM2
Phase Monitor2
PM1
Phase Monitor1
Y2A*
Aquastat Stage2
RA*
Aquastat Power (24VAC)
Y1A*
Aquastat Stage1
CA*
Aquastat Power (Ground)
2
Plenum Heat Stage2
1
Plenum Heat Stage1
C
Plenum Heat Common
AR
Airflow Reductions
24VAC
Power
ODFLO
Outdoor Flow Switch
IDFLO
Indoor Flow Switch
L
Thermostat Lockout Indicator
E
Thermostat Emergency Heat
O
Thermostat Heat/Cool
W2
Thermostat Auxiliary Heat
Y2
Thermostat Stage2
Y1
Thermostat Stage1
G
Thermostat Fan
R
Thermostat Power (24VAC)
C
Thermostat Power (Ground)
*NOTE: There is no need for an external aquastat for most systems, since the Setpoint Control Method provides built-in aquastat
functionality.
ISSUE 03: 1-Oct-2021
24vac input for detection of optional outdoor unit.
Not used.
Not used.
Not used.
Not used.
Used only for external aquastat control *.
Used only for external aquastat control *.
Used only for external aquastat control *.
Electric auxiliary heat stage 1 (turns on or off).
Electric auxiliary heat stage 2 (turns on or off).
Ground for electric auxiliary heat control.
24vac input for reduction of airflow by the AR percent factor.
24vac output for AR above.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Connect to R through dry contact to enable fan recirculation mode.
Not used.
Not used.
Page 87