Table A1 - Control Board Connector Descriptions (Top); Table A2 - Control Board Connector Descriptions (Left Side) - Maritime Geothermal Nordic PC Series Installation And Service Manual

Table of Contents

Advertisement

The tables describe the connections starting with the top of the board and working around the board counter clock-wise.

TABLE A1 - Control Board Connector Descriptions (Top)

Signal
Description
HPS1
High Pressure Sensor 1
LPS1
Low Pressure Sensor 1
EEV1
Local EEV
TS1
Suction Line Temperature 1
EEV2
Remote EEV
TS2
Suction Line Temperature 2
HPS2
High Pressure Sensor 2
LPS2
Low Pressure Sensor 2
HTS
Outdoor Temperature
CTS
Auto Calibration
I_IN
Indoor Loop IN
I_OUT
Indoor Loop OUT
O_IN
Outdoor Loop IN
O_OUT
Outdoor Loop OUT

TABLE A2 - Control Board Connector Descriptions (Left Side)

Name
Description
PWM_IN
Signal for PWM IN
IN_SPARE
Spare digital input
COM_IN
Common for PWM IN
PWM4
PWM / 0-10VDC output
PWM3
PWM / 0-10VDC output
PWM2
PWM / 0-10VDC output
PWM1
PWM / 0-10VDC output
GND
Ground
HZC
Hot Zone Circulator
CZC
Cold Zone Circulator
ICR
Internal Circulator Relay
DO_3
Digital output
DO_2
Digital output
DO_1
Digital output
DO_0
Digital output
LC
Loop common (ground)
L6
Loop6
L5
Loop5
L4
Loop4
L3
Loop3
L2
Loop2
L1
Loop1
C(SH)
Soaker Hose common
SH
Soaker Hose
ISSUE 03: 1-Oct-2021
Measures compressor discharge pressure.
Measures compressor suction pressure.
EEV
Mounted to suction line.
Not used.
Not used.
Not used.
Not used.
Not used.
Resistor in connector for auto-calibration reference (32°F—0°C).
Not used.
Mounted in dry well on pool water IN pipe inside unit.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Control signal for fan in optional outdoor unit.
Not used.
Not used.
Not used.
Signal for dry contact pool pump control (CP1 And CP2).
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.
Not used.