Mitsubishi Electric D700 Quick Start Manual page 12

Table of Contents

Advertisement

D700 QUICK START MANUAL
n CHANGING THE PARAMETER SETTING VALUE
Change the Pr. 1 Maximum frequency setting.
O
p
r e
t a
o i
n
1.
Screen at powering on
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Press
to choose the parameter setting
mode.
4.
Turn
until
(Pr. 1) appears.
5.
Press
to read the present set value.
"
"(120.0Hz (initial value)) appears.
6.
Turn
to change the set value to
"
" (60.00Hz).
7.
Press
to set.
Turn
to read another parameter.
Press
to show the setting again.
Press
twice to show the next parameter.
Press
twice to return to frequency monitor.
NOTES
to
is displayed ... Why?
Write disable error
Write error during operation
Calibration error
Mode designation error
The number of digits displayed on the operation panel is four. Only the
upper four digits of values can be displayed and set. If the values to be
displayed have five digits or more including decimal places, the fifth or
later numerals can not be displayed nor set.
(Example) For Pr. 1
When 60Hz is set, 60.00 is displayed.
When 120Hz is set, 120.0 is displayed and second decimal place is not
displayed nor set.
n SETTING DIAL PUSH
Push the setting dial to display the set frequency* currently set.
* Appears when PU operation mode or external/PU combined
operation mode 1 is selected (Pr. 79 = "3").
12
MitsubishiElectric Automation, Inc.
D
s i
p
a l
y
PU indication is lit.
PRM indication is lit.
(The parameter number read previously
appears.)
Flicker...Parameter setting complete!!