8.

Technical data

8.1

Dimensions and weights

Property
Dimensions (W x H x D)
Weight (without accessories)
8.2

Specifications

Property
Rated voltage U(V)
Rated power P(W)
Degree of protection
8.3
Temperature, humidity and
atmospheric pressure
8.3.1

Ambient temperature

Property
Storage and transportation
Operation
Measurement accuracy
Battery charging temperature
8.3.2

Humidity

Property
Storage and transportation
Operation
Measurement accuracy
8.3.3
Atmospheric pressure
Property
Storage and transportation
Operation (at 25 °C and 24 h)
Measurement accuracy
8.4

Noise emissions

< 70 dB(A)
8.5

Power supply unit

Property
Frequency
Input voltage (AC)
Input current
Output voltage (DC)
Output current
Robert Bosch GmbH
Value/Range
200 x 280 x 110 mm
7.9 x 11.0 x 4.3 inch
1,5 kg
3.3 lb
Value/Range
19 DC
60
IP 30
Value/Range
5 °C – 40 °C
41 °F – 104 °F
5 °C – 40 °C
41 °F – 104 °F
10 °C – 35 °C
50 °F – 95 °F
0 – 45°C
Value/Range
30 % – 60 %
20 % – 80 %
30 % – 60 %
Value/Range
700 hPa – 1060 hPa
700 hPa – 1060 hPa
700 hPa – 1060 hPa
Value/Range
50 Hz – 60 Hz
100 V~ – 240 V~
1,5 A
19 V
3,7 A
Technical data | FSA 500 | 31
8.6

Battery

Property
Battery life
Charging time for battery capacity
> 70 %
(with battery flat and FSA 500
switched off; charging time increas-
es with parallel measurements)
8.7

Bluetooth Class 1 and 2

Radio link Class 1 (100 mW)
Free field workshop environment
For measurements in vehicle engine
compartment
Radio link Class 2 (10 mW)
Free field workshop environment
For measurements in vehicle engine
compartment
8.8

Signal generator

Function
Amplitude
Signal forms
Frequency range
Max. output current
Impedance
Symmetry
Curve generation
Short-circuit proof with respect
to interference voltage, static
Short-circuit proof with respect
to interference voltage, dynamic
Additionally:
R
Automatically activated filters and attenuators
for enhanced signal quality.
R
Automatic shut-off in the case of short circuit,
detection of interference voltage on starting signal
generator.
en
Value/Range
< 4 h
< 1 h
Minimum range
30 m
10 m
Minimum range
3 m
1 m
Specification
- 10 V – 12 V
(load < 10 mA) to ground
DC, sinusoidal, triangular,
square-wave
1 Hz – 1 kHz
75 mA
approx. 60 Ohm
10 % – 90 %
(triangular, square-wave)
Output rate up to
100000 values/s,
resolution 8 bit,
Y full range adjustable
(bit), unipolar / bipolar
operation