Connecting the hob to the mains power supply
The power supply should be connected in compliance with the relevant standard, or a
single-pole circuit breaker. The method of connection is shown below.
for 220-240V earthedone-phase
connection,bridges connect 1-2
terminals and 4-5 terminals,
safety wire to
For 380-415V 2N~ earthed
two- phase connection,bridges connect
4-5 terminals ,the safety wire to
For 380-415V 2N~ earthed
two- phase connection,the safety
wire to
1.If the cable is damaged or needs replacing, this should be done by an after-sales
technician using the proper tools, so as to avoid any accidents.
2.If the appliance is being connected directly to the mains supply, an omnipolar circuit
breaker must be installed with a minimum gap of 3mm between the contacts.
3.The installer must ensure that the correct electrical connection has been made and that
it complies with safety regulations.
4.The cable must not be bent or compressed.
5.The cable must be checked regularly and only replaced by a properly qualified person.
H05VV-F3G2,5
H05VV-F4G2,5
H05VV-F5G1,5