1.2 Self-controlled safety edge SOFA1-SOFA2
Command
SAFETY TEST
SOFA1-SOFA2
1
0
41
24V=
SAFETY TEST
1
6
N.C.
OPENING SAFETY DEVICE
1
7
N.C.
CLOSING SAFETY DEVICE
1
8
N.C.
REVERSAL SAFETY DEVICE Connect the output contact of device SOFA1-SOFA2 to terminals 1-8
1.3 Outputs and accessories
Output
Value
1
+
24 V= / 0,5 A
0
-
24 V= / 3 W
1
11
(0,125 A)
24 V= / 3 W
1
12
(0,125 A)
24 V= / 3 W
1
13
(0,125 A)
24V= / 50 W
0
14
0
15
24V= / 1,2 A
0
15
12V~ / 15 W
U
W
V
230 V~ / 2,5 A
M1
120 V~ [LOGICMJ]
X
Z
Y
230 V~ / 2,5A
M2
120 V~ [LOGICMJ]
230 V~ / 100 W (0,4 A)
W
N
120 V~ [LOGICMJ]
230 V~ / 100 W (0,4 A)
X
L
120 V~ [LOGICMJ]
Function
Accessories power supply. Power supply output for external accessories, including
automation status lamp.
Automation open lamp. Only with limit switch 0-11 (NC) connected and in one motor
mode (jumper OM=OFF) will the lamp extinguish when automation is closed.
Automation closed lamp. Only with limit switch 0-12 (NC) connected and in one motor
mode (jumper OM=OFF) will the lamp extinguish when automation is open.
Automation open lamp. A lamp lights up that extinguishes only when automation is
closed.
Flashing light (LAMPH). Activated during opening and closing operations.
(2 A)
24 V electric block. Activated upon every opening command.
24 V electric motor brake. With JR6=OFF, OM=OFF and DIP5=ON, the output is
active for the entire duration of the opening or closing motion.
24 V electric lock. With EO=OFF the output is on and the automation is closed.
12 V electric lock. Connect the supplied 8.2 Ω / 5 W resistance in series. Activated
upon every opening command.
Motor 1 (M1). Terminal W must be connected to the common motor phase connection.
The condenser must be connected between the U and V phases.
Note: if the direction of rotation of the motor is incorrect for the desired direction of
movement, swap the U and V phases.
Motor 2 (M2). Terminal Z must be connected to the common motor phase connection.
The condenser must be connected between the X and Y phases.
Note: if the direction of rotation of the motor is incorrect for the desired direction of
movement, swap the X and Y phases.
Flashing light (LAMP). Activated during opening and closing operations.
Courtesy light. In 1 motor mode only (jumper OM=OFF and no motor connected to
terminals X-Z-Y), a courtesy light may be connected, which activates for 180 s each
time a total or partial opening command or closing command is received.
Membrane push-button panel (PT3). Starts the opening operation.
Note: to activate the closing operation, connect the connector of the push-button panel
to J7 (rotated by 180°).
Membrane push-button panel (PT3). Causes the blocking of the movement.
Membrane push-button panel (PT3). Starts the closing operation.
Note: to activate the opening operation, connect the connector of the push-button panel
to J7 (rotated by 180°).
Insert the SOFA1-SOFA2 electronic board on the control panel.
Connecting terminal 41 enables a safety edge test cycle before every
operation.
If the test fails the SA led flashes and the test is repeated.
Connect the output contact of device SOFA1-SOFA2 to terminals 1-6
on the control panel (in series with the photocell output contact, if
installed).
Connect the output contact of device SOFA1-SOFA2 to terminals 1-7
on the control panel (in series with the photocell output contact, if
installed).
on the control panel (in series with the photocell output contact, if
installed).
Attention: for quick operation on the safety edge, connect it to contact
1-6 or to contact 1-7.
Description
13
Description
LOGICM - IP1854