GENERAL SAFETY WARNINGS

This installation manual is intended for professionally
competent personnel only.
The installation, the power connections and the settings must
be completed in conformity with Good Working Methods and
with the regulations in force. Before installing the product,
carefully read the instructions. Bad installation could be ha-
zardous.
The packaging materials (plastic, polystyrene, etc.) should not
be discarded in the environment or left within reach of children,
as these are a potential source of hazard. Before beginning the
installation check that the product is in perfect condition.
Do not install the product in explosive areas and atmospheres:
the presence of flammable gas or fumes represents a serious
threat to safety.
The safety devices (photocells, sensitive edges, emergency
stop, etc.) must be installed taking into account: the provisions
and the directives in force, Good Working Methods, the instal-
lation area, the functional logic of the system and the forces
developed by the motorised door or gate.
Before making power connections, check that the rating
corresponds to that of the mains supply A multipolar di-
sconnection switch with a contact opening gap of at least 3 mm
must be included in the mains supply. Check that upstream of
the electrical installation an adequate residual current circuit
breaker and an overcurrent cut out are fitted. When requested,
connect the motorised door or gate to an effective earthing
system carried out as indicated by current safety regulations.
During installation, maintenance and repair operations, cut
off the power supply before opening the cover to access the
electrical parts.
To handle electronic parts, wear earthed antistatic conductive
bracelets. The manufacturer of the motorisation declines
all responsibility in the event of components which
are not compatible with the safe and correct operation of the
product. For repairs or replacements of products only original
spare parts must be used.

INSTALLATION WARNING

Secure the control panel permanently. Drill a hole into the lower
side of the container so as to run the cables through it. Secure
the cables, if they are accessible, by means of appropriate
gland plates (not provided by us). Keep the line and motor con-
ductors separate (at least 8 mm) from the control conductors at
the terminal board connection points (for example, by means
of clamps). Connect the line and motor protection conductors
(yellow-green) by means of the transformer and control panel
using the clamp provided. At the end of the installation to close
again the container.

EC DECLARATION OF CONFORMITY

Manufacturer:
DITEC S.p.A.
Address:
via Mons. Banfi, 3
21042 Caronno P.lla (VA) – ITALY
Herewith declares that the control panel LOGICM is in conformity
with the provisions of the following EC directives:
Low Voltage Directive 2006/95/EC;
EMC Directive 2004/108/EC.
Caronno Pertusella,
06-09-2006
Fermo Bressanini
(President)
105

TECHNICAL DETAILS

Power supply
Fuse F1
Fuse F2
1 motor output
2 motors output
Accessories power
supply
Temperature
Protection degree
Dimensions
APPLICATIONS
11
164
187
LOGICM
LOGICMJ
230 V~ / 50Hz
120 V~ / 60Hz
F6,3A
F6,3A
F3,15A
F3,15A
230 V~ / 5 A max 120 V~ / 6,3 A max
230 V~
120 V~
2 x 2,5 A max
2 x 3,15 A max
24 V= / 0,5 A
24 V= / 0,5 A
-20° C / +55° C
-20° C / +55° C
IP55
IP55
187x261x105
187x261x105