Electronic controller
Hide thumbs Also See for PCO2 Series:

Advertisement

Quick Links

cod. +050003520 - rel. 1.2 - del 26/11/01
pCO
2
Controllore elettronico PCO2**** / Electronic controller PCO2****
J1
1
G
G0
3
15
B1
B2
J2
4
B3
GND
+VDC
B4
J3
5
BC4
B5
BC5
17
2
VG
VG0
Y1
J4
6
Y2
Y3
Y4
ID1
ID2
ID3
ID4
J5
7
ID5
14
ID6
ID7
ID15H
ID8
ID15
J21
J19
IDC1
8
IDC15
ID16
B6
B7
ID16H
J6
4
11
B8
GND
ID9
J22
J7
ID10
7
Y5
ID11
6
Y6
ID12
B9
IDC9
BC9
ID13H
J20
5
B10
J8
ID13
8
BC10
J23
IDC13
12
ID 17
ID14
ID 18
7
ID14H
IDC17
Vi ringraziamo per la scelta fatta, sicuri che sarete soddisfatti del vostro acquisto.
Caratteristiche generali
pCO
2
è un controllore elettronico a microprocessore, sviluppato da Carel per molteplici applicazioni nel settore del
condizionamento dell'aria e della refrigerazione. Assicura la più assoluta versatilità di applicazione, consentendo di realizzare
prodotti specifici su richiesta del cliente. pCO
morsetti necessari alla connessione verso i dispositivi controllati (ad esempio: valvole, compressori, contattori di potenza,
ventilatori). Esso prevede l'orologio di serie su tutte le versioni, con batteria al litio.
Il programma e i parametri sono memorizzati su FLASH-MEMORY, consentendo il loro mantenimento anche in caso di
mancanza di alimentazione (senza la necessità di una batteria di mantenimento). Il caricamento del programma può essere
eseguito a mezzo PC o tramite apposita chiave di programmazione/espansione di memoria. pCO
alla rete locale pLAN (pCO Local Area Network) già prevista per il modello precedente di controllore pCO.
La rete pLAN è costituita da più controllori e più terminali, che interagiscono tra loro. Ogni controllore in rete pLAN può
scambiare informazioni (qualsiasi variabile, digitale o analogica, a seconda del programma applicativo utilizzato) con velocità di
trasmissione elevata. Possono essere collegate fino a 31 unità, tra pCO
tempi molto brevi. Il collegamento verso la linea seriale di supervisione/teleassistenza secondo lo standard RS485, viene realizzato
tramite l'inserimento sul pCO
Legenda
1.
connettore per l'alimentazione [G (+), G0 (-)]
2.
LED giallo indicazione presenza tensione di alimentazione e LED rosso di allarme overload
3.
fusibile 250 Vac, 2 A ritardato (T2 A)
4.
ingressi analogici universali NTC, 0/1 V, 0/10 V, 0/20 mA, 4/20 mA
5.
ingressi analogici passivi NTC, PT1000, ON/OFF
6.
uscite analogiche 0/10 V
J9
9
7.
ingressi digitali a 24 Vac/Vdc
8.
ingressi digitali 230 Vac o 24 Vac/Vdc
9.
connettore per il terminale sinottico (pannello esterno con segnalazioni dirette)
J10
10
10. connettore per tutti i terminali standard della serie pCO
11. uscite digitali a relè
Rx-/Tx-
12. connettore per la connessione alla scheda di espansione
J11
13
Rx+/Tx+
13. connettore, indirizzamento e LED per la rete locale pLAN
GND
14. sportello per l'inserimento della scheda seriale RS485 per supervisore o RS232 per l'interfacciamento modem o ECHELON
16
15. sportello per l'inserimento della scheda per la connessione ad una stampante parallela
16. sportello per l'inserimento della scheda per l'espansione di memoria o per la chiave di programmazione
17. terminale built-in (LCD, tasti e LED)
13
Versioni base disponibili:
• SMALL (cod. PCO2000AS0), MEDIUM (cod. PCO2000AM0), LARGE (cod. PCO2000AL0), senza terminale built-in
• SMALL (cod. PCO2000BS0), MEDIUM (cod. PCO2000BM0), LARGE (cod. PCO2000BL0), con terminale built-in
A richiesta è possibile la fornitura di controllori con uscite digitali a relè a stato solido (SSR); 24 Vac/Vdc, P
Alimentazione
C1
Nell'installazione si deve utilizzare un trasformatore di sicurezza in Classe II di almeno 50 VA, per l'alimentazione di un solo
NO1
controllore pCO
2
. Si raccomanda di separare l'alimentazione del controllo pCO
NO2
J12
mentazione del resto dei dispositivi elettrici (contattori ed altri componenti elettromeccanici) all'interno del quadro elettrico.
NO3
Qualora il secondario del trasformatore sia posto a terra, verificare che il conduttore di terra sia collegato al morsetto G0.
C1
Attenersi a ciò per tutti i dispositivi connessi al pCO
C4
che siano rispettati i riferimenti G e G0 (il riferimento G0 deve essere mantenuto per tutte le schede).
NO4
J13
In caso di utilizzo della rete pLAN, richiedere il manuale pCO
NO5
NO6
Ulteriori specificazioni e notizie si possono reperire sul manuale di installazione - cod. +030221820.
C4
AVVERTENZA: il pCO
2
(a differenza del pCO) non può alimentare i terminali grafici PCOT00PGH0 e PCOI00PGL0, che
C7
devono quindi essere alimentati con altre sorgenti.
J14
NO7
Caratteristiche tecniche
C7
NO14
Caratteristiche meccaniche
NO8
C14
dimensioni
versione SMALL inseribile su 13 moduli DIN, 110 x 227.5 x 60 mm
J15
C8
NC14
versione MEDIUM e LARGE inseribili su 18 moduli DIN, 110 x 315 x 60 mm
NC8
NO15
montaggio
su guida DIN
C15
Contenitore plastico
NC15
• agganciabile su guida DIN secondo norme DIN 43880 e CEI EN 50022
C9
C16
• materiale: tecnopolimero
NO9
• autoestinguenza: V0 (secondo UL94) e 960 °C (secondo IEC 695)
NO16
NO10
J16
• prova biglia: 125 °C
NO17
NO11
• resistenza alle correnti striscianti: 250 V
NO18
C9
• colore: grigio RAL7035
C16
• feritoie di raffreddamento
NO12
J17
Caratteristiche elettriche
C12
11
alimentazione (controllore con term. connesso)
NC12
E-
morsettiera
NO13
E+
C13
J18
GND
CPU
NC13
memoria programma (su FLASH MEMORY)
memoria dati (RAM statica)
memoria dati parametri
Fig. 1
durata ciclo utile (applicazioni media complessità) 0,5 s (tipico)
2
è dedicato all'esecuzione del programma di regolazione ed è dotato del set di
2
permette anche la connessione
2
e terminali, in modo da condividere le informazioni in
2
di schede seriali opzionali con il protocollo di comunicazione Carel, MODBUS™ o ECHELON
2
e per il download del programma applicativo
max
2
e terminale (o più pCO
2
e terminali) dalla ali-
2
. Se si alimentano più schede pCO
2
collegate in rete pLAN, assicurarsi
2
Carel.
22÷40 Vdc e 24 Vac ±15% 50/60 Hz - assorbimento massimo P= 14W
con connettori maschio/femmina estraibili, tensione max 250 Vac
sez. cavo: min. 0,5 mm
2
- max 2,5 mm
2
H83002 a 16 bit e 14 MHz
1 MB organizzata a 16 bit (espandibile fino a 6 MB)
256 kB organizzata a 16 bit (espandibile fino a 1 MB)
4 kB organizzata a 16 bit (limite max: 400.000 scritture per locazione di memoria)
GB
Thank you for your choice. We trust you will be satisfied with your purchase.
General features
pCO
2
is an electronic controller based on a microprocessor designed by Carel for a wide range of applications in the
Air-Conditioning and Refrigeration sectors. pCO
2
is a flexible controller, which can respond to all customer requirements.
pCO
2
carries out the regulation program and it is provided with a set of terminals that connect it to the controlled devices
(e.g. valves, compressors, power contactors, fans). All pCO
The program and the parameters are stored on FLASH-MEMORY, thus allowing their permanence even in case of power fai-
lure (it is not necessary for you to have a maintenance battery).
The program can be loaded through PC or by means of a suitable programming key/memory expansion. pCO
connection to the local pLAN network (pCO Local Area Network) - already provided in the pCO controller previous version.
The pLAN network is made up of several controllers and terminals which interact among themselves. Every controller in the
pLAN network can exchange information (any digital and analog variable according to the application program being used)
at a high speed of transmission. In order to rapidly exchange information, up to 31 units - pCO
connected to the pLAN network.
The connection towards the supervising/telemaintenance serial line, according the RS485 standard, is carried out by
®
.
inserting the optional serial cards on the pCO
2
with the standard Carel communication protocol, MODBUS™ or ECHELON
Legenda
1.
power supply connector [G (+), G0 (-)]
2.
yellow LED indicating mains power and red LED for alarms
3.
250Vac, 2A slow-blow fuse (T2A).
4.
universal analog inputs NTC, 0/1V, 0/10V, 0/20mA, 4/20mA
5.
passive analog inputs NTC, PT1000, ON/OFF
6.
analog outputs 0/10V
7.
24Vac/Vdc digital inputs
8.
230Vac or 24Vac/Vdc digital inputs
9.
connector for synoptic terminal (external panel with direct signallings)
10. connector for all pCO
2
series standard terminals and for the application program download
11. relay digital outputs
12. connector for connection to the expansion card
13. connector, addressing and LED for pLAN local network
®
14. hatch for inserting RS485 serial card for supervisor or RS232 serial card for modem interfacing or ECHELON
15. hatch for inserting the card for connection to a parallel printer
16. hatch for inserting the FLASH-MEMORY expansion card or for programming key
17. built-in terminal (LCD, buttons and LEDs)
Standard models available:
• SMALL (cod. PCO2000AS0), MEDIUM (cod. PCO2000AM0), LARGE (cod. PCO2000AL0), without built-in terminal
• SMALL (cod. PCO2000BS0), MEDIUM (cod. PCO2000BM0), LARGE (cod. PCO2000BL0), with built-in terminal
= 10 W.
It is possible, upon request to provide controllers with SSR digital outputs; 24Vac/Vdc, P
Power supply
During installation a safety Class II transformer rated at least 50VA must be used to supply only one pCO
It is advisable to keep separate the pCO
2
and terminal (or more pCO
devices (contactors and other electromechanical components) in the electric panel. If the transformer secondary winding is
grounded, check that the ground cable is connected to G0 terminal. Proceede as mentioned for all devices connected to
pCO
2
.
If more than one pCO
2
board, connected to the pLAN, must be powered, please check if G and G0 references are observed
(G0 reference must be kept in every board). If using the pLAN network, ask for the Carel pCO
Further information can be found in the installation manual - code +030221820.
WARNING: pCO
2
can not supply graphic terminals PCOT00PGH0 and PCOI00PGL0 which can be supplied by other sources.
Technical Specifications
Mechanical Specifications
dimensions
SMALL board models can be mounted on 13 DIN modules, 110x227.5x60mm
MEDIUM and LARGE board models can be mounted on 18 DIN modules, 110x315x60mm
mounting
on DIN rail
Plastic case
• it can be fastened on DIN rail according to DIN 43880 and CEI EN 50022 standards
• material: technopolymer
• self-extinguishing: V0 (complying with UL94) and 960°C (complying with IEC 695)
GB
• ball pressure test:125°C
• comparative tracking index: 250V
• colour: RAL7035 grey
• cooling vent-holes
Electrical specifications
power (controller with terminal connected)
22÷40Vdc and 24Vac ±15% 50/60Hz - P= 14W maximum absorption
terminal block
with removable-screw male/female connectors - max. voltage: 250Vac
cable cross-section: min. 0.5mm
CPU
H83002, 16 bit and 14MHz
program memory (on FLASH MEMORY)
1 MB organized in 16 bit (it can be expanded up to 6 MB)
data memory (static RAM)
256 kB organized in 16 bit (it can be expanded up to 1 MB)
parameter data memory
4 kB organized in 16 bit (max limit: 400.000 writes per memory location)
operating cycle delay (with applic. of average complexity) 0.5s (typical value)
2
models are equipped with a clock, that includes lithium battery.
2
allows the
2
and terminals - can be
®
.
®
= 10W.
max
2
controller.
2
and terminals) from the power supply of the other electric
2
user's manual.
2
– max. 2.5mm
2

Advertisement

loading
Need help?

Need help?

Do you have a question about the PCO2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carel PCO2 Series

  • Page 1 è un controllore elettronico a microprocessore, sviluppato da Carel per molteplici applicazioni nel settore del is an electronic controller based on a microprocessor designed by Carel for a wide range of applications in the condizionamento dell'aria e della refrigerazione. Assicura la più assoluta versatilità di applicazione, consentendo di realizzare Air-Conditioning and Refrigeration sectors.
  • Page 2 3 cm di distanza dai connettori. Carel si riserva la possibilità di apportare modifiche o cambiamenti ai propri prodotti senza alcun preavviso. / Carel reserves the right to alter the features of its products without prior notice. CAREL srl Via dell’Industria, 11 - 35020 Brugine - Padova (Italy)

This manual is also suitable for:

Pco2 largePco2 mediumPco2 small