Checking The Wheel Bolt Torque; Service Every 100 Hours; Cleaning The Air Cleaner Primary Element [Double Element Type] - Kubota MX5200 Operator's Manual

Hide thumbs Also See for MX5200:
Table of Contents

Advertisement

SERVICE EVERY 50 HOURS
5. Make sure that the engine shuts off after
approximately 1 second.
6. If the engine does not stop, consult your local
KUBOTA Dealer for servicing the operator's seat.

4. Checking the wheel bolt torque

WARNING
To avoid personal injury or death:
• Never operate the tractor with a loose rim,
wheel, or axle.
• Any time that the bolts and nuts are loosened,
retighten them to the specified torque.
• Check all bolts and nuts frequently and keep
them tight.
1. Check the wheel bolts and nuts regularly especially
when they are new.
2. If the bolts and nuts of the wheels are loose, tighten
them as follows.
(1) Bolt (front wheel)
Bolt (front wheel)
(1)
Tightening
torque
Bolt (rear wheel)
(2)

SERVICE EVERY 100 HOURS

1. Cleaning the air cleaner primary
element [Double element type]
IMPORTANT :
• The air cleaner uses a dry element. Never apply
oil.
• Do not run the engine with the filter element
removed.
• Do not touch the secondary element except in
cases where replacing is required.
MX5200
(2) Bolt (rear wheel)
124.0 N⋅m to 147.0 N⋅m
(12.6 kgf⋅m to 15.0 kgf⋅m)
[91.5 ft⋅lbs to 108.4 ft⋅lbs]
196.0 N⋅m to 225.0 N⋅m
(20.0 kgf⋅m to 23.0 kgf⋅m)
[144.6 ft⋅lbs to 166.0 ft⋅lbs]
(See Replacing the air cleaner primary element
and secondary element on page 96.)
(1) Secondary (safety) element
(2) Primary element
1. Remove the cover of the air cleaner and the
primary element.
2. Clean the primary element.
3. When dry dust adheres to the primary element,
blow compressed air from the inside, turning the
primary element.
Pressure of compressed air must be under the
following value.
Pressure of compressed air
4. When carbon or oil adheres to the primary element,
follow the following procedure.
a. Soak the primary element in detergent for 15
minutes.
b. Then wash the primary element several times in
water.
c. Rinse the primary element with clean water.
d. Dry the primary element naturally.
e. After the primary element is fully dried, inspect
the inside of the primary element with a light
and check if it is damaged or not.
5. Replace the primary element of the air cleaner.
Be sure to perform once yearly or after every sixth
cleaning, whichever comes first.
IMPORTANT :
• Be sure to refit the cover with the arrow
(on the rear of cover) upright. If the cover is
improperly fitted, the evacuator valve will
not function and dust will adhere to the
primary element.
Evacuator valve
1. Open the evacuator valve once a week under
ordinary conditions or daily when used in a dusty
place to get rid of large particles of dust and dirt.
 PERIODIC SERVICE
(3) Cover
(4) Evacuator valve
205 kPa
2
(2.1 kgf/cm
)
[30 psi]
87