SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL

Maintenance

1.
A.

General

(1)
The Indoor Unit should be isolated from the UAV power network prior to any maintenance to
avoid any possibility of personnel being irradiated.
B.

Cleaning

(1)
The Indoor Unit and antenna can both be cleaned with a microfibre or soft cotton cloth
dampened with clean water.
(2)
Chemical cleaning agents should not be used.
C.

Inspection

(1)
The Indoor Unit and antenna should be inspected every year for general condition and integrity
of the mounting and connectors.
(2)
The cables should be inspected every year for general condition, chafing kinking and routing.
(3)
The electrical cross-bonding between the indoor unit and the antenna should be tested ever 2
years.
D.

Servicing

(1)
There are no adjustments, lubrication or scheduled servicing tasks needed for the satcom
terminal while installed on the UAV.
(2)
The satcom terminal is not field repairable.