Omron SYSMAC CXONE-ALC-EV2 Series Operation Manual page 39

Cx-drive
Table of Contents

Advertisement

Creating New Drive Files
22
Note
(1) Modbus-RTU Slave Address Setting:
The Modbus-RTU slave address (01 to 32) is set in the following param-
eter using the Digital Operator on front of the Inverter before connecting
the CX-Drive.
Inverter Series
Parameter No.
(2) The Servo Communications Unit No. (0 to F) is set using the following
method before connecting the CX-Drive.
Servo Series
Method
Via PLC (DeviceNet) Connections (3G3MV, 3G3RV)
Network Tab Page
• Slave Unit Address: 0 to 63 (DeviceNet
slave address)
• Master Unit Address: 0 to 15 (DeviceNet
unit number)
Via PLC (MCH/MECHATROLINK-II) or
Via PLC (NCF/MECHATROLINK-II) (R88D-WN)
Network Tab Page
• Axis Number: 1 to 32 for MCH or
1 to 16 for NCF
• Master Unit Address: 0 to 15 (MCH or
NCF unit number)
3G3JV
n70
n153
R7D-AP
Unit number rotary switch on
the Servo
Click the Properties Button to set the
PLC (with a DeviceNet Unit) to use as the
gateway.
Click the Properties Button to set the
PLC (with a MCH or NCF Unit) to use as
the gateway.
Section 2-2
3G3MV
3G3RV
H5-01
3 R88D-WT
Change to the Setting Mode
using the Servo front panel
settings and set the unit num-
ber in digit 2 of Pn000.
Gateway PLC Tab Page
Gateway PLC Tab Page