Omron SYSMAC CXONE-ALC-EV2 Series Operation Manual page 33

Cx-drive
Table of Contents

Advertisement

Creating New Drive Files
Other Connections
1,2,3...
16
1. Select Tool - Options . Alternately click the Settings Button in the Autode-
tection Dialog Box
The Options Dialog Box will be displayed.
2. Click the Autodetect Options Tab and then select one or more connection
types other than Direct .
For Inverters:
• Via PLC (DeviceNet)
• Via PLC (SCU/SCB)
For Servos:
• Via PLC (MCH/MECHATROLINK II)
• Via PLC (NCF/MECHATROLINK II)
• Via PLC (SCU/SCB)
3. Click the OK Button.
4. Select File - Autodetect.
5. Click the Start Button in the Autodetection Dialog Box. The rest of the pro-
cedure is the same as for a direct serial connection.
Section 2-2