Start the test sequence
When the script configuration is done, you can start the test sequence.
1
Press the
soft key when ready.
Follow the step by step guidances to conduct the link characterization sequence.
2
- Press
to Start a SM-OTDR test. (This will start a 1310/1550/1625 nm OTDR test).
- When asked to "CHECK PMD SOURCE", contact far end of fiber under test and connect OBS-550/500 light source. Turn light
source on, ensure BB mode of operation, PMD mode and press Activate. Red light will come on indicating light source is active.
- Press
to continue PMD test.
- Upon completion of PMD test, instruct tech at far end to press AP mode of operation on light source.
- Press
to continue AP test.
- Upon completion of AP test, instruct tech at far end to press CD mode of operation on light source.
- Press
to continue CD test.
After completion of CD test, Result screen appears.
If more fibers are to be tested press
and fiber number automatically increments.
If no more fiber is to be tested press
and a summary of the results is visible.
3
Press soft key
to exit the link characterization script.
To see details of the tests, press Results hard key and application soft key at the bottom of the on-screen.
OBS-500/550 LightSource Operation for Fiber Characterization Testing
Press the Power button
to turn on.
1
2
Using the MODE button to select BB
.
(1)
3
When instructed by the technician performing the tests, using the
is green.
4
Under
, press the button to activate the source.
When directed by the testing technician, using the
5
OBS-550 has HD mode which is High dynamic mode. By selecting HD mode, the EDFA amplifier built into the light source is
engaged and the output power increases substantially. In addition, the spectral range of the light source goes from 1460-
1640 to 1530–1565 nm.
8000 Platform - Quick Card "Fiber Characterization Script" – V1.3 - September 2011 – Ref.: E8000M02QCFC1 - Copyright 2011 JDSU. All rights reserved
button ensure PMD light
button ensure AP light is green, then CD.
8000 PLATFORM QUICK CARD
FIBER CHARACTERIZATION SCRIPT
GETTING STARTED
The following procedure describes how to configure a T-BERD/MTS 8000 platform with a MTAU 4-port module and how to start the
Automated Fiber Characterization Script. Please read the entire procedure BEFORE starting.
Inspect and clean connectors
Before connecting a fiber into a test module, inspect and clean the module bulkhead and the fiber jumper connectors.
!
-
Use video inspection scope to verify the connector quality.
-
Use appropriate cleaning material (e.g. IBC™ cleaner, cotton swab, dust air sprays, etc...).
Connecting the test modules to the MTAU
Connect the OTDR module to the MTAU port A with a jumper.
1
Connect the OFI module (FOX port) to the MTAU port B with a jumper.
2
3
Connect the DISPAP module to the MTAU port C with a jumper.
Connect the BBS module to the MTAU port D with a jumper.
4
DISPAP (CD/PMD/AP)
The test modules (OTDR, DISPAP and OFI) have to be located in the slots closest to the mainframe. Keep the MTAU and BBS
modules at the back slots.
Repeat step 1 and 4 for the second unit.
5
Referencing the Test Functions
The Insertion Loss (IL), the Optical return Loss (ORL), the Chromatic Dispersion (CD) and the Attenuation Profile (AP)
1
measurements have to be referenced before starting testing.
Please refer to dedicated quick cards for the associated procedures
8000 Platform - Quick Card "Fiber Characterization Script" - V1.3 - September 2011 – Ref.: E8000M02QCFC1 - Copyright 2011 JDSU. All rights reserved
BBS2A
MTAU 4
D
C
B
Jumper A
A
Fiber under Test
COM
OTDR
OFI (IL/ORL)
Need help?
Do you have a question about the T-BERD/MTS 8000 and is the answer not in the manual?