    5.4. Basic settings (end limits and angular travel) 1. INTRODUCTION The J4 io actuator is designed to drive the external venetian blind, types 1 & 2. What is io-homecontrol®? The J4 io uses io-homecontrol®, the new universal and secure wireless communica- tion protocol, shared by the major manufacturers in the world of home automation.
  • Page 3: Safety

    - The motor, torque and operating time must be adjusted according to the complete installation. - Only Somfy original accessories should be used (adapters, brackets, connectors, power cable, etc.). - Fitting, testing, commissioning and repair of the installation must only be carried out by qualified personnel.
  • Page 4: Installation

    • Screw the 2 adaptors (1) using 2 M3x8 bolts (2) on the motor shaft. Tightening torque = 1.1 Nm Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. • If necessary, compress the edge of the head rail (4) into the motor zone.
  • Page 5: 57 X 51 Mm Head Rail, Open Above

    • Screw the 2 adaptors (1) using 2 M3x8 bolts (2) on the motor shaft. Tightening torque = 1.1 Nm Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. • Insert the motor into the head rail (4).
  • Page 6: 67 Mm Head Rail, Open Below

    • Screw the 2 adaptors (1) using 2 M3 x 8 bolts (2) on the motor shaft. Tightening torque = 1.1 Nm Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. • Fit the two head rail adaptors (8) on the motor.
  • Page 7 • Screw the 2 adaptors (1) using 2 M3 x 8 bolts (2) on the motor shaft. Tightening torque = 1.1 Nm Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. • Fit the two head rail adaptors (8) on the motor.
  • Page 8: 66 Mm Head Rail, Open Below

    3.6 J4 io Plate The J4 io plate is supplied connected to the motor; it must be integrated into or on the outside of the head rail. If Somfy sensor is being used, the plate must be fixed to the outside of the head rail.
  • Page 9: Wiring

    Mounting inside the head rail Mounting outside the head rail • The mounting of the J4 io plate inside the head rail is compatible with the following head rails and shafts: HEAD RAIL SHAFT 57 x 51 mm Up to 14 mm hex...
  • Page 10: Commissioning

    5. COMMISSIONING The guide only describes commissioning using a Situo mobile io VB type Somfy io local control point which provides greater precision when tilting the slats. For commissioning using any other io control point, refer to the corresponding guide.
  • Page 11: Checking The Motor's Direction Of Rotation

    5.4. basic settings 5.4.1. Setting upper and lower end limits Check that your J4 io actuator has been assembled in the blind in the lowered position with the slats closed. • Press the Up button for 3 seconds. The blind rotates in the up direction.
  • Page 12: Programming The First Somfy Io Local Control Point

    • Briefly press the PROG button on this control point: the blind moves briefly; the control point has been programmed. Checking the settings 5.6. Check the settings of the upper and lower end limits using the Somfy io local control point. © 2011 Somfy SAS. All rights reserved. 11/2011...
  • Page 13: Operation

    A long press on the Up or Down buttons will cause the blind to raise or lower completely. 6.2. Operating with a Somfy sensor or automatic function Refer to the corresponding manual for the Somfy io sensor. 7. MODIFICATION OF THE SETTINGS 7.1. Favourite position (my) 7.1.1.
  • Page 14: Adding/Deleting Somfy Io Control Points And Io Sensors

    7.2. Adding/Deleting Somfy io control points and io sensors Refer to the corresponding guide. 7.3. Modifying the end limits 7.3.1. Modifying the upper end limit • Place the blind in the intermediate position. • Press the Up and Down buttons for 5 seconds the blind moves briefly.
  • Page 15: Modifying The Angular Travel

    7.4. Modifying the angular travel For optimum operation of the J4 io actuator, it is essential to adjust the angular travel. The angular travel is the total angle necessary for the blind to change from a slats closed position to a slats fully open position.
  • Page 16: Tips And Recommendations

    Pairing or setting has been not Only cut shortly the power and repeat the react as described executed correctly. procedure if necessary. in the manual during pairing or setting. © 2011 Somfy SAS. All rights reserved. 11/2011...
  • Page 17: Replacing A Lost Or Broken Somfy Io Control Point

    8.3. Replacing a component of the actuator If necessary it is possible to physically replace the J4 io motor, the J4 io plate, or both. In all circumstances, in order to have an operational installation, the following procedure must be carried out: •...
  • Page 18: Technical Data

    For the J418, the maximum permissible torque for an end of the motor shaft is 12 Nm. Thermal time J4 io motors are protected by a thermal cut-out in case of overheating caused by continuous use for longer than 6 minutes.