  • Page 1 J4 io Notice installateur Installationsanleitung Guida d’installazione Installer Guide...
  • Page 2 Lunghezza motore (mm) Livello di potenza acustica Per il J418, la coppia massima ammessa per una estremità di asse motore è di 12 Nm. Tempo termico un utilizzo continuo superiore a 6 minuti. © 2013 Somfy SAS. All rights reserved. 06/2013...
  • Page 3: Table Of Contents

    10. Technical data angular travel) 1. INTRODUCTION The J4 io actuator is designed to drive the external venetian blind, types 1 & 2. What is io-homecontrol®? The J4 io uses io-homecontrol®, the new universal and secure wireless communication protocol, shared by the major manufacturers in the world of home automation.
  • Page 4: Safety

    - The motor, torque and operating time must be adjusted according to the complete installation. - Only Somfy original accessories should be used (adapters, brackets, connectors, power cable, etc.). - Correct operation of the installation is only guaranteed if the installation and assembly have been carried out according to best practices, if the electrical supply is adequate and if maintenance is carried out.
  • Page 5: Compatibility

    The J4 io motor has been designed to operate horizontally: 10° maxi 3. COMPATIBILITY The J4 io motor has a degraded performance with EVB having operation position kinematic. Operation position kinematics : © 2013 Somfy SAS. All rights reserved. 06/2013...
  • Page 6: Installation

    Screw the 2 adaptors (1) using 2 M3x8 bolts (2) on the motor shaft. Tightening torque = 1,35 N.m +/- 20% Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. If necessary, compress the edge of the head rail (4) into the motor zone.
  • Page 7: 57 X 51 Mm Head Rail, Open Above

    Screw the 2 adaptors (1) using 2 M3x8 bolts (2) on the motor shaft. Tightening torque = 1,35 N.m +/- 20% Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. Insert the motor into the head rail (4).
  • Page 8: 67 Mm Head Rail, Open Below

    Screw the 2 adaptors (1) using 2 M3 x 8 bolts (2) on the motor shaft. Tightening torque = 1,35 N.m +/- 20% Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. Fit the two head rail adaptors (8) on the motor.
  • Page 9 Screw the 2 adaptors (1) using 2 M3 x 8 bolts (2) on the motor shaft. Tightening torque = 1,35 N.m +/- 20% Ensure that the J4 io plate cable does not pass over a rotating part of the motor or mechanism. Fit the two head rail adaptors (8) on the motor.
  • Page 10: 66 Mm Head Rail, Open Below

    Using the clips (5), attach the motor in the head rail (4). 4.6 J4 io Plate The J4 io plate is supplied connected to the motor; it must be integrated into or on the outside of the 191 mm © 2013 Somfy SAS. All rights reserved. 06/2013...
  • Page 11 Mounting inside the head rail Mounting outside the head rail The mounting of the J4 io plate inside the head rail is compatible with the following head rails and shafts: HEAD RAIL SHAFT 57 x 51 mm Up to 14 mm hex...
  • Page 12: Wiring

    Earth (Yellow/Green) 6. COMMISSIONING The guide only describes commissioning using a Situo mobile io VB type Somfy io local control point which provides greater precision when tilting the slats. For commissioning using any other io control point, refer to the corresponding guide.
  • Page 13: Pre-Programming The Somfy Io Local Control Point

    6.4. Basic settings 5.4.1. Setting upper and lower end limits Check that your J4 io actuator has been assembled in the blind in the lowered position with the slats closed. Press the Up button for 3 seconds. The blind rotates in the up direction.
  • Page 14: Checking The Settings

    PROG button on this control point: the blind 6.6. Checking the settings Check the settings of the upper and lower end limits using the Somfy io local control point. © 2013 Somfy SAS. All rights reserved. 06/2013...
  • Page 15: Operation

    A long press on the Up or Down buttons will cause the blind to raise or lower completely. 7.2. Operating with a Somfy sensor or automatic function Refer to the corresponding manual for the Somfy io sensor. 8. MODIFICATION OF THE SETTINGS 7.1. Favourite position (my) 7.1.1.
  • Page 16: Adding/Deleting Somfy Io Control Points And Io Sensors

    8.2. Adding/Deleting Somfy io control points and io sensors Refer to the corresponding guide. 8.3. Modifying the end limits 8.3.1. Modifying the upper end limit Place the blind in the intermediate position. Press the Up and Down buttons for 5 seconds the blind...
  • Page 17: Modifying The Angular Travel

    8.4. Modifying the angular travel For optimum operation of the J4 io actuator, it is The angular travel is the total angle necessary for the blind to change from a slats closed position to a slats fully open position. The slats fully open position is reached when the slats no longer tilt and the blind makes an initial raising movement.
  • Page 18: Modifying The Position Of The Horizontal Slats

    The sensor is paired/set. Readjust the angular travel. horizontal position. The "my" position is cleared. Set the "my" position. © 2013 Somfy SAS. All rights reserved. 06/2013...
  • Page 19 Readjust the angular travel and then reset The angular travel is incorrectly set. cannot be repeated. the "my" favourite position. No solution by adjusting the J4 io. Recall the ladders. «my» position from the lower end limit. The blind (or one of...
  • Page 20: Replacing A Lost Or Broken Somfy Io Control Point