Table Of Contents - Bryant LEGACY 558J Product Data

Single package rooftop cooling unit 3 to 6 nominal tons
Table of Contents

Advertisement

ARI CAPACITY RATING
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
Your Bryant rooftop unit (RTU) was designed by customers for customers. With "no- - strip" screw collars, handled access
panels, and more we've made your unit easy to install, easy to maintain, easy to use, and easy to love.
Easy to install:
All 558J units are horizontal. No special adapter curbs are necessary. Convertible airflow design makes it easy to adjust to
unexpected job- - site complications. Lighter units make easy replacement. Bryant 3- - 6 ton 558J rooftops fit on existing
Bryant curbs. Also, our large control box gives you room to work and room to mount Bryant accessory controls.
Easy to maintain:
Bryant's easy access handles provide quick and easy access to all normally serviced components. Our "no- - strip" screw
system has superior holding power and guides screws into position while preventing the screw from stripping the unit's
metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite
plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Now, you can take
refrigeration system pressure readings without affecting the condenser airflow.
Easy to use:
Bryant rooftops have high and low pressure switches, a filter drier, and 2" filters standard. Bryant's terminal board puts all
your connections and troubleshooting points in one place, standard. Most low voltage connections are made to the same
board and make it easy to find what you're looking for and easy to access it.

TABLE OF CONTENTS

PAGE
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
3
COOLING TABLES
4
STATIC PRESSURE TABLES
5
8
OUTDOOR AIR INTAKE & EXHAUST PERF
10
11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
TYPICAL WIRING DIAGRAM
18
2
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
PAGE
20
24
25
33
34
36
45
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents