Electrical Info - Bryant LEGACY 558J Product Data

Single package rooftop cooling unit 3 to 6 nominal tons
Table of Contents

Advertisement

Table 30 – 558J*06
VOLTAGE
RANGE
V ---PH ---HZ
MIN
MAX
208--- 1--- 60
187
253
230--- 1--- 60
187
253
208--- 3--- 60
187
253
230--- 3--- 60
187
253
460--- 3--- 60
414
506
575--- 3--- 60
518
633
Table 31 – 558J*07
VOLTAGE
RANGE
V ---PH ---HZ
MIN
MAX
208--- 3--- 60
187
253
230--- 3--- 60
187
253
460--- 3--- 60
414
506
575--- 3--- 60
518
633
ELECTRICAL INFORMATION (CONT)
COMP (ea)
OFM (ea)
RLA
LRA
WATTS
FLA
26.2
134
325
1.5
26.2
134
325
1.5
15.6
110
325
1.5
15.6
110
325
1.5
7.7
52
325
0.8
5.8
39
325
0.6
COMP (ea)
OFM (ea)
RLA
LRA
WATTS
FLA
19.0
12
325
1.5
19.0
12
325
1.5
9.7
62
325
0.8
7.4
50
325
0.6
Max
TYPE
WATTS
AMP Draw
Std Static
1000
Med Static
1850
Std Static
1000
Med Static
1850
Std Static
1000
Med Static
2120
High Static
2615
Std Static
1000
Med Static
2120
High Static
2615
Std Static
2120
Med Static
2615
High Static
2615
Std Static
2120
Med Static
3775
High Static
3775
Max
TYPE
WATTS
AMP Draw
Std Static
2120
Med Static
2615
High Static
3775
Std Static
2120
Med Static
2615
High Static
3775
Std Static
2120
Med Static
2615
High Static
3775
Std Static
2120
Med Static
3775
High Static
3775
35
5 TONS
IFM
Max
EFF at Full Load
5.1
70%
7.4
78%
5.1
70%
7.4
78%
5.1
70%
5.5
80%
7.9
81%
5.1
70%
5.5
80%
7.9
81%
2.7
80%
3.6
81%
3.6
81%
2.1
80%
2.9
81%
2.9
81%
6 TONS
IFM
Max
EFF at Full Load
5.5
80%
7.9
81%
10.7
81%
5.5
80%
7.9
81%
10.7
81%
2.7
80%
3.6
81%
5.0
81%
2.1
80%
2.9
81%
2.9
81%
FLA
4.9
7.0
4.9
7.0
4.9
5.2
7.5
4.9
5.2
7.5
2.6
3.4
3.4
2.0
2.8
2.8
FLA
5.2
7.5
10.2
5.2
7.5
10.2
2.6
3.4
4.8
2.0
2.8
2.8