Siemens SITRANS DA400 Operating Instructions Manual page 79

Process monitoring
Table of Contents

Advertisement

Output
Digital outputs
For connection to intrinsically safe switching amplifiers according to DIN 19234 with:
Rated conditions
Installation conditions
Climate class
Installation site
Mechanical load
Degree of protection according to EN 60 529
Electromagnetic compatibility
SITRANS DA400 for material flow monitoring with protection against explosion
Operating Instructions, 09/2007, A5E00841152-01
Binary outputs
Signal status Low (no response)
Signal status High (no response)
Maximum supply voltage U
Maximum short circuit current I
Maximum power P
i
Internal capacity C
i
Internal inductance L
i
Spurious emission and interference immunity
6
Clamps 31 and 32
Clamps 41 and 42
Clamps 51 and 52
Clamps 61 and 62
Clamps 71 and 72
Clamps 81 and 82
≤ 1.2 mA (Source: DIN 19234)
≤ 2.1 mA (Source: DIN 19234)
≤ 15.5 V
i
≤ 25 mA
i
≤ 64 mW
≤ 5.2 nF
Negligible
Vertical wall mounting, cables fed in from below
Class 4K4 according to EN 60721-3-4
Zone 1 or zone 2
Class 4M3 according to EN 60721-3-4
IP65
According to EN 61326
Technical data
9.1 Device technical data