Siemens SITRANS DA400 Operating Instructions Manual page 50

Process monitoring
Table of Contents

Advertisement

Operation
6.4 Parameter menu
Parameter
Parameter
no.
name
P.25
P ouT
P.26
INP1
P.27
INP2
P.28
INP3
P.29
INP4
P.30
AL I1
P.31
AL I2
P.32
AL I3
P.33
AL I4
P.34
do I1
P.35
do I2
P.36
do I3
P.37
do I4
P.38
bUSNr
P.41
DMP1
P.42
DMP2
P.43
DMP3
P.44
DMP4
See also
Parameter lock (Page 52)
50
Parameter value
PoS / inv
oFF
24 V
¬24 V
0-20
4-20
20-0
20-4
noPA
As P.26
As P.26
As P.26
-5.0% to 105.0%
-5.0% to 105.0%
-5.0% to 105.0%
-5.0% to 105.0%
oFF, do1, do2, do3, do4, do5,
do6, ¬do1, ¬do2, ¬do3, ¬d04,
¬do5, ¬do6
As P.34
As P.34
As P.34
0 to 126
0 to 30
0 to 30
0 to 30
0 to 30
Factory
Meaning
setting
PoS
Output polarity
oFF
Function of universal input 1:
Without function
24 V digital signal > 7 V -> High, passive
normally open contact closed-> High
¬24 V digital signal < 4.5 V -> High, passive
normally open contact open -> High
Analog signal 0 to 20 mA->0 to 100%
Analog signal 4 to 20 mA->0 to 100%
Analog signal 20 to 0 mA->0 to 100%
Analog signal 20 to 4 mA->0 to 100%
Parameter lock
Function of universal input 2
Function of universal input 3
Function of universal input 4
105.0%
Universal input 1 alarm
(analog current function only)
105.0%
Universal input 2 alarm
(analog current function only)
105.0%
Universal input 3 alarm
(analog current function only)
105.0%
Universal input 4 alarm
(analog current function only)
oFF
Status signal assignment
Universal input 1
oFF
Status signal assignment
Universal input 2
oFF
Status signal assignment
Universal input 3
oFF
Status signal assignment
Universal input 4
126
PROFIBUS address
0
Low-pass filter time acoustic channel 1
0
Low-pass filter time acoustic channel 2
0
Low-pass filter time acoustic channel 3
0
Low-pass filter time acoustic channel 4
SITRANS DA400 for material flow monitoring with protection against explosion
Operating Instructions, 09/2007, A5E00841152-01