Connecting
4.2 Connecting MASS 2100/FC300
Cable requirements
Cables must be suitable for the temperature (at least 70 °C) and be flammability-rated to at
least V-2.
A: Prepare the cable by stripping it at both ends.
Figure 4-1
B: Connect wires within the sensor terminal compartment
1. Remove the lock screw and remove the lid.
2. Undo the flexible strap.
3. Disconnect the sensor connection (white plug) from the electronic.
4. Loosen the mounting screw using a TX10 Torx driver and remove the electronic from the
housing.
5. Remove the cap and the ferrule from the cable gland and slide onto the cable.
6. Push the cable through the open gland and anchor the cable shield and the wires with the
clamp bar.
7. Remove the terminal block from the electronic.
32
WARNING
Cable end
SITRANS MASS 2100 & FC300 (FCT010)
Compact Operating Instructions, 05/2020, A5E40504094-AB