B. Dial Timer Control Panel
1
SURECOOK
0
MINUTES
5
60
55
50
45
30
40
35
2
3
POWER ON
4
RESET
5
TIMED
MANUAL
MODEL
NO.
6
SERIAL
NO.
Figure 4-2
Dial Timer
Control Panel
1. SURECOOK Indicator Light
This light is lit whenever the cooking
•
compartment is below cooking temperature.
Note: When in the Timed mode, the timer will not
•
count down when this light is ON.
2. TIMER
The Dial Timer sets the operating time from 0 to
•
60 minutes.
10
Turn the knob clockwise until it points to the
•
15
required time.
20
When the Timer reaches 0, a buzzer sounds for
•
3 seconds.
25
The Dial Timer does NOT work in Manual Mode.
•
3. POWER ON Indicator Light
When the Green indicator light is ON, power is
•
ON to the controls.
4. RESET Indicator lights when the High Limit circuit is
open. The light stays ON, and a buzzer sounds until
the appliance is reset.
To reset:
Turn OFF power to the steamer with the Main
•
Power ON/OFF LEVER.
Wait 15 minutes for the appliance to cool.
•
Make sure the probes are clean.
•
Follow the Power ON instructions.
•
If the appliance needs reset again, see the
•
Operator's Troubleshooting Guide.
5. TIMED/MANUAL Switch selects the manual or timed
operating mode.
6. Serial Number/Model Number Insert.