Installation; Clearance Requirements; Shipping Damage Instructions - Cleveland SGL-30-T1 Operator's Manual

Gas t1 skillets
Hide thumbs Also See for SGL-30-T1:
Table of Contents

Advertisement

GENERAL
Installation of the unit must be accomplished by
qualified installation personnel working to all applicable
local and national codes. Improper installation of
product could cause injury or damage.
This equipment is built to comply with applicable
standards for manufacturers. Included among those
approval agencies are: UL, A.G.A., NSF, ASME/N.Bd.,
CSA, CGA, ETL, and others. Many local codes exist,
and it is the responsibility of the owner/installer to
comply with these codes.
Observe all clearance requirements to provide proper
make-up air flow. Do not obstruct the flow of combustion
and ventilation air. Check rating plate to ensure that unit
has been equipped to operate with the type of gas
available at the installation.
Dimensions and clearance requirements are shown on
the Specification Sheet.
INSPECTION / UNPACKING
1. Before unpacking visually inspect the unit for
evidence of damage during shipping.
2. If damage is noticed, do not unpack the unit, follow
"SHIPPING DAMAGE INSTRUCTIONS" shown below.
3. Carefully remove unit from shipping carton. Remove
any packing material from unit. After carefully
unpacking check for "concealed" damage. If
damage is noticed, follow "SHIPPING DAMAGE
INSTRUCTIONS" shown below.
4. A protective material has been applied to the
stainless steel panels. This material must be
removed immediately after installation, as heat will
melt the material and make it more difficult to
remove.
SHIPPING DAMAGE
INSTRUCTIONS
If shipping damage to the unit is discovered or
suspected, observe the following guidelines in
preparing a shipping damage claim.
1. Write down a description of the damage or the
reason for suspecting damage as soon as it is
discovered. This will help in filling out the claim
forms later.
2. As soon as damage is discovered or suspected,
notify the carrier that delivered the shipment.
3. Arrange for the carrier's representative to examine
the damage.
4. Fill out all carrier claims forms and have the
examining carrier sign and date each form.

INSTALLATION

CLEARANCE REQUIREMENTS

This unit must be installed in accordance with the
clearances shown on the rating label which is adhered
to the unit.
FOR YOUR SAFETY. Keep the appliance area free and
clear of combustible materials.
INSTALLATION
1. Position the unit in it's permanent location, and level
the unit by turning the adjustable feet.
2. Once positioned
and leveled,
permanently
secure the unit's
rear flanged feet to
the floor using
5/16" lag bolts and
floor anchors
(supplied by the
installer). Three
bolts are required to secure each of the flanged
feet.
3. Seal joints of flanged feet with a silicone sealant.
GAS
ENSURE THE GAS SUPPLY MATCHES THE UNIT'S
REQUIREMENTS AS STATED ON THE RATING
PLATE.
It is recommended that a sediment trap (drip leg) be
installed in the gas supply line. If the gas pressure
exceeds 14" water column, a pressure regulator must
be installed, to provide a maximum of 14" water column
gas pressure to the gas control valve.
Connect the gas line to the manual valve located at the
rear of the control box.
Installation must be in accordance with local codes
and/or the National Fuel Gas Code ANSI Z223.1 Latest
Edition (USA) or the latest Installation Codes for Gas
Burning Appliances and Equipment CAN/ CGA B149.1
(natural gas) and CAN/ CGA B149.2 (propane gas).
Use a gas pipe joint compound which is resistant to L.P.
gas. Test all pipe joints for leaks with soap and water
solution. Ensure that the gas pressure regulator is set
for the manifold pressure indicated on the gas rating
plate.
The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psi (3.45 kPa). The appliance must be
isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.45 kPa).
4 7/8" (124mm)
120
120
7/16"Ø, 3 HOLES
ON 3 1/8" (80mm) B.C.D.
FLANGED FOOT DETAIL
(REAR LEGS ONLY
)