HINGE ADJUSTMENT INSTRUCTIONS
1.
FULLY LIFT COVER
TO RELEASE SPRING
TENSION
SPRING
LUBRICATION PROCEDURE
Lubricate the following parts every three months to
insure smooth operation and reduce wear.
Trunnion Housing
Grease Nipple
MAINTENANCE
WARNING
Any maintenance or service involving disassembly of components
should be made by a qualified service technician. Ensure gas,
electrical and water supply (if applicable) to the unit are shut off.
TRUNNIONS
On the left hand side of
the skillet there are two
grease nipples on the
top back portion of the
trunnion housing.
3.
WHEN PROPERLY
ADJUSTED, COVER
SHOULD REST AT 70˚
2.
USING A
7/16" DEEP
SOCKET
ADJUST LEFT
AND RIGHT
BOLTS
EVENLY