INDOOR UNIT INSTALLATION
Refer to the following diagram to ensure proper distance from walls and ceiling:
15cm (5.9in) or more
12cm (4.75in)
or more
2.3m (90.55in) or more
STEP 2: ATTACH MOUNTING PLATE TO WALL
The mounting plate is the device on which you will mount
the indoor unit.
1.
Remove the screw that attaches the mounting plate to
the back of the indoor unit.
2.
Place the mounting plate against the wall in a location
that meets the standards in the Select Installation Loca-
tion step. (See Mounting Plate Dimensions for detailed
information on mounting plate sizes.)
3.
Drill holes for mounting screws in places that:
• have studs and can support the weight of the unit
• correspond to screw holes in the mounting plate
4.
Secure the mounting plate to the wall with the screws
provided.
5.
Ensure the mounting plate is flat against the wall.
NOTE FOR CONCRETE OR BRICK WALLS:
If the wall is made of brick, concrete, or similar material, drill
5mm-diameter (0.2in-diameter) holes in the wall and insert the
sleeve anchors provided. Then secure the mounting plate to
the wall by tightening the screws directly into the clip anchors.
12cm (4.75in)
or more
fig 3.1
STEP 3: DRILL WALL HOLE FOR
CONNECTIVE PIPING
You must drill a hole in the wall for refrigerant piping, the
drainage pipe, and the signal cable that will connect the
indoor and outdoor units.
1.
1. Determine the location of the wall hole based on
the position of the mounting plate. Refer to Mounting
Plate Dimensions on the next page to help you deter-
mine the optimal position. At minimum, the wall hole
should be 65mm (2.5in) diameter, and at a slightly
lower angle to facilitate drainage.
2.
Using a 65mm (2.5in) or 90mm(3.54in) (depending
on models) core drill, drill a hole in the wall. Make
sure that the hole is drilled at a slight downward an-
gle, so that the outdoor end of the hole is lower than
the indoor end by about 5mm to 7mm (0.2-0.275in).
This will ensure proper water drainage. (See Fig. 3.2)
3.
Place the protective wall cuff in the hole. This protects
the edges of the hole and will help seal it when you
finish the installation process.
When drilling the wall hole, make sure to avoid wires,
plumbing, and other sensitive components.
44
Wall
Indoor
Fig.3.2
fig 3.2
CAUTION
EN
Outdoor

Hide quick links: