Download Print this page
ABSCO SHEDS CYCWKUTK Assembly & Instruction Manual

ABSCO SHEDS CYCWKUTK Assembly & Instruction Manual

Large gable shedn3/c1 frame kit

Advertisement

Quick Links

AU: 1800 029 701
NZ: 0800 466 444
This instruction manual is to be used during
the initial construction of the structure.
This kit is applicable to the following sheds:
60303WK
3060UTK
52233WK
3052UTK
45302WK
3045UTK
45232WK
The addition of this frame kit will increase the
wind rating of the specified sheds to
Wind rating: N3/C1 as per AS4055-2012.
Suitable for specific cyclonic regions
DOWNLOAD
OUR APP FOR
ASSEMBLY
VIDEOS
Absco Industries
Assembly Instruction Manual
LARGE GABLE SHED
N3/C1 FRAME KIT
FOR WORKSHOP & UTILITY MODELS
admin@absco.com.au
www.abscosheds.com.au
Where information conflicts with the original
instruction manual, this document is to be
referenced.
View of frame kit applied to
WARNING: This shed must be anchored to a
100mm thick concrete slab with the concrete
anchors supplied.
Failure to do so will result in the shed not
having the structural integrity required to
endure a severe storms or cyclonic event.
WARNING: Doors must remain closed with
all padbolts properly secured during severe
storms or cyclonic event.
LEAVE A REVIEW
Tell us about your experience and
receive a $20 Coles Gift Card.
Visit www.abscosheds.com.au/review
Model: CYCWKUTK
60303WK
02/03/21
1.3
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the CYCWKUTK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ABSCO SHEDS CYCWKUTK

  • Page 1 Suitable for specific cyclonic regions storms or cyclonic event. LEAVE A REVIEW DOWNLOAD OUR APP FOR Tell us about your experience and ASSEMBLY receive a $20 Coles Gift Card. VIDEOS Visit www.abscosheds.com.au/review Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 2: General Instructions

    Sensible shoes are highly recommended. • Do not erect your shed in windy conditions. • It is highly recommended to erect the shed with two or more people. RECOMMENDED Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 3 20mm Tab notch + 45mm Lip notch 20mm Tab notch + 45mm Lip notch on both ends 45mm Lip One end: 20mm Tab notch + 45mm Lip notch notch SPECIAL NOTCHING, not noted above. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 4: Fittings And Accessories

    DRIVER BIT APEX 3MM DRILL DRILL ZACO194 PLATE RIDGE CONNECTOR ZACO9A FAST015 DYNABOLT PLATE HEX HD M10 DYNABOLT ANCHOR TEK SCREW W/ NEO M10 NUT & BOLT FAST033 BRACKET (12 PK) WASHER 10-16x16mm Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 5 *Dimension taken from edge of slab to centreline of portal frame. Slab size specified in original manual. 2 portal frame layout: 45302WK 45232WK - Not to scale NOTE: One portal frame is supplied in original kit Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 6 Slab dimension specified in 2 portal frame layout: original manual. 3052UTK 3045UTK - Not to scale NOTE: One portal frame is supplied in original kit Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 7 Start slowly, begin to drill the tek screw into the metal. Once the tek screw has stabilised while drilling increase the speed until the tek screw threads ‘bite’ into the metal. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 8 - Do not screw any boxed sections until they have been correctly sized as the specific step instructs. - Roof section, door frames and upright door studs are singular pieces. - Use self drilling tek screws for all assembly and installation of these sections. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 9 Additional framing is supplied in this frame kit. K0285 (x8) and C1785 (x2) All other frame parts are supplied in the original shed kit. NOTE: These frames will need to be trimmed by 25mm to suit a rebated slab Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 10 NOTE: These frames will need to be trimmed by 25mm to suit a rebated slab. 2300 Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 11: Anchoring Methods

    Double door openings are required to be anchor through a BKT17. Fixed by four tek anchored using BKT12. It is fixed to the screws. midpoint of the doorway channel with four tek screws as shown. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 12 ANCHORING LAYOUT Slab dimensions below illustrate the minimum required anchors per wall. Ensure that anchors are evenly spaced along wall. 6060mm for 6.0m wall 5323mm for 5.2m wall 4580mm for 4.5m wall Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 13 INSTALL EXTRA FASTENERS Absco sheds sheets have punched holes typically spaced at 592mm from centre to centre. To achieve a cyclonic wind rating additional screws will need to be installed to reduce these distances.
  • Page 14 Pre-drill from inside the shed through the top channel and into the wall sheet at 148mm centres, (every pan) and then fix with a screw. Do this on the non-gable walls only. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 15 3. Make sure the frame is square and fi x with and level surface and use one tek screw at a second tek screw at each join. each join. 4. Turn frame over and repeat last step. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 16 10. Drill 10mm holes in the jamb above the door (ref image ‘B’) and the channel below the door (ref image ‘C’). These align with the vertical padbolt shafts of double doors. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 17 TIP 2: Take a single piece of wood at 890mm. This will act as a height template to mark the drilling positions when outside the shed to fix the internal bracing. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 18 Now fasten all boxed frame sections to the non-gable wall from the outside of the shed. This task is best done with two people. Secure the wall bracing to the portal frame using a BKT17 and tek screws on either side as shown. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 19 4. Fix roof panel to the top of the stud using BKT 17 as shown below. HEX HD TEK SCREW W/ NEO WASHER 10-16x16mm BKT17 fixed to roof sheet with 6 hex hd tek screws with neoprene washers from outside. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 20 5. Use corner brackets (BKT10) to secure the rear, side and front wall braces together. Position as shown and fix using four tek screws. Pre-drilling the bracket with a 3mm drill bit will make this easier. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 21 8 tek screws as shown. The roof lip may need to be removed in order to fit the four tek screws from the outside of the Two multipurpose shed. brackets, BKT17, are used per roof brace. Absco Industries Assembly Instruction Manual Model: CYCWKUTK 02/03/21...
  • Page 22 Absco Sheds Storage Guidelines • Absco Sheds are designed to be weatherproof for normal weather conditions. In the event of extreme weather conditions such as heavy rain, combined with high wind gusts, the ridge capping, sheeting joins, screw fi xings etc., may exhibit minor deformations which may allow some water entry. These areas should be checked regularly to ensure that maximum strength and protection is maintained.
  • Page 23 Lifetime Warranty Statement This warranty against defects is given by: Absco Industries (ABN: 77 869 708 678) Address: PO Box 119 Acacia Ridge QLD 4110 Ph: 1800 029 701 Fax: 07 3344 1191 Email: admin@absco.com.au Date of issue: 19 December 2018 Details of Manufacturer’s Warranty This product comes with a Lifetime structural warranty from the date of purchase.
  • Page 24 IMPORTANT 1. Manufacturer’s Disclosure This warranty against defects shall not apply in the following situations: A) Where the product is not assembled in accordance with the instructions provided in the product kit; B) Where the product is used to store corrosive materials such as fertilizer, chlorine etc; C) The warranty does NOT cover damage caused by storms, wind, rain, snow or poor foundations;...