4. Insert the new feed roller into its
5. After done, put the roller cover back into its compartment.
NOTE:
•
•
56
ArtixScan DI 5240/5250/5260 User's Manual
compartment:
a)
Mount the roller with a white cap
at the right of the roller into the
roller shaft at the right side of the
compartment.
b)
Hold the lever and move the roller
shaft to the right horizontally.
Then, insert it into a hollow at the left
side of the roller until it sticks into
place.
c)
Rotate the lever on the roller shaft up
to fasten the roller.
The recommended replacement point for your Feed Roller Assembly is after
scanning approximately 150,000 scans through the feeder.
Please contact your local resellers for purchasing new Feed Roller Assembly.
Roller shaft
Lever
Roller shaft