Omron ZS Series Communication Command Reference page 35

Zero smart sensor
Hide thumbs Also See for ZS Series:
Table of Contents

Advertisement

Unit No.
Data No.
03h
02h
03h
03h
03h
04h
03h
05h
03h
06h
04h
00h
04h
01h
05h
00h
07h
00h
07h
02h
07h
06h
07h
0Dh
07h
0Eh
07h
11h
07h
25h
07h
26h
07h
27h
Setting Value Obtaining and Changing Command
Setting range/
Parameter
output range
Glass thickness
0: STOP
measurement
1: Moving
mode
0: None
1: Filter size 2
Image smoothing
2: Filter size 4
level
3: Filter size 8
4: Filter size 16
Background
0 to 255 (tone)
removing level
before addition
Background
0 to 4095 (tone)
removing level after
addition
0: 0 %
1: 12.5 %
2: 25%
3: 37.5 %
Edge threshold
4: 50%
5: 62.5 %
6: 75%
7: 87.5 %
0: OFF
Mutual interference
1: ON
prevention mode
0: Timing A
Timing setting
1: Timing B
Gain setting
1 to 5
0: Auto
Emitted light amount
1: Auto range
setting (Area 1)
2: Fixed
0: Peak
Light amount
1: Surface
control target area
2: 2 areas
3: 3 areas
Emitted light
0 to 1000 (X0.1%)
amount fixed level
Emitted light
0 to 800 (X0.1%)
amount lower limit
Emitted light amount
0 to 800 (X0.1%)
upper limit
0: Surface
Measurement target
1: 2 areas
area
2: 3 areas
Received light
0 to 4095 (tone)
amount (surface)
Received light
0 to 4095 (tone)
amount (2 areas)
Received light
0 to 4095 (tone)
amount (3 areas)
CompoWay/F Communication Command Reference
Section 3
Remarks
Parameters when
[Glass material]=[FILM/
OTHERS]
Parameters when [Mutual
interference prevention
mode]=[ON]
(Note 1)
Parameters when [Emitted light
amount setting]=[Fixed]
Parameters when [Emitted light
amount setting]=[Auto range]
ZS Series
3-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs-ldcZs-mdcZs-dsu

Table of Contents