SECOND TIMED OUTPUT: This wire provides a (-) 200mA output whenever the remote button(s) con-
trolling Channel 4 is pressed. This output can be programmed to provide the following types of out-
puts (see also the Feature Menus section):
Validity: Output that will send a signal as long as the transmission is received.
Latched: Output that will send a signal when the Channel 4 button(s) is pressed and will continue
until the same button(s) is pressed again.
Latched, reset with ignition: Similar to the latched output, this type of output turns on the first
time the Channel 4 button(s) is pressed and turns off the next time the same button is pressed.
This type of output additionally stops and resets whenever the ignition is turned on and then off.
30-second timed: Output that will send a continuous signal for 30 seconds.
90-second timed: Output that will send a continuous signal for 90 seconds.
2-11 CHANNEL 5 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/90
SECOND TIMED OUTPUT: Channel Five can be programmed for these output configurations. The unit
is set to the default validity output. To change the configuration, use the two-chirp setting to toggle
through the different configurations. Refer to channel 4 feature 2-10 for additional detail.

menu #3 - remote start options

3-1 ENGINE CHECKING ON/OFF: In the default setting the remote start will monitor either the vehi-
cle's tach wire or voltage depending on the programming of feature 3-2. If programmed OFF the
vehicle will crank for the programmed crank time (feature 3-5) and will not verify with tach or volt-
age that the car is running. In the OFF setting, if the vehicle fails to start, the ignition can stay on for
the entire run duration. Using tach or voltage check is always recommended if possible.
3-2 CHECKING TYPE TACH/VOLTAGE: Selects the method of engine monitoring. If set to TACHOME-
TER the unit will reference the learned tach signal to disengage the starter. In addition it will moni-
tor the RPM and shut down if the engine RPM is too high or too low. When set to VOLTAGE, the unit
will crank the starter for the programmed time and then attempt to sense that the engine is running
by detecting an increase in voltage. The threshold for the voltage check is selectable in feature 3-6.
3-3 RUN TIME 12, 24, 60 MINUTES: Selects the time in minutes that the system will operate
the engine until the system "times out". This is the maximum operation period and the system
may be shut down using a shutdown at any time. Using the Pro Security Programmer, the run time
can be programmed for any duration from 1-60 minutes.
3-4 PARKING LIGHTS FLASHING/CONSTANT: In the default setting, the unit will flash the vehicle's
parking lights (if connected) while remote started. The constant setting will turn the parking lights on
solid for the entire run duration.