H1/5; H1/6; H1/7 - Clarion SR1000 Installation Manual

Clarion sr1000 cctv systems: installation guide
Hide thumbs Also See for SR1000:
Table of Contents

Advertisement

H1/5 GREEN (-) door trigger input, zone 3
Most vehicles use negative door trigger circuits. Connect the green wire to a wire which shows
ground when any door is opened. In vehicles with factory delays on the domelight circuit, there is
usually a wire that is unaffected by the delay circuitry. This wire will report Zone 3.
H1/6 BLUE (-) multiplex input, zone 4
Inputs shorter than 0.8 seconds will trigger the warning response, while inputs longer than 0.8 seconds
will trigger the full alarm sequence. If installing an optional dual stage sensor, connect both the blue and
the green wires of the optional sensor to this input. This wire will report Zone 4.
H1/7 VIOLET (+) door trigger input, zone 3
This wire is used in vehicles that have a positive (+) switched dome light circuit. Connect the violet
wire to a wire that shows (+)12V when any door is opened, and ground when the door is closed.
This wire will report Zone 3.

Hide quick links: