Section 6 − Operating The Welding Generator; Engine Controls - Miller DU-OP Owner's Manual

Dual-operator engine driven welding generator
Table of Contents

Advertisement

SECTION 6 − OPERATING THE WELDING GENERATOR
.
When facing the front panel, the Welder B controls and weld terminals are on the right and the Welder A side controls and weld terminals are on
the left.

6-1. Engine Controls

.
See Section 6-3 for weld control
descriptions.
1
Engine Start Button
2
Stop Switch
3
Ether Starting Aid Switch (Optional)
Push switch up and release while cranking
engine to release ether.
To Start: Press button and use Ether switch
(if necessary). Release button when engine
starts.
.
If the engine does not start, let engine
come to a complete stop before attempt-
ing restart.
3
1
4
5
225 543 / 804 289-A
To Stop: Push switch down and hold. Re-
lease when engine stops.
4
Battery Charging Warning Light
Light goes on when battery is not charging.
NOTICE − If light goes on, stop engine and
check alternator and engine belt.
5
Engine Hour Meter
OM-225 590 Page 37