Chapter 6 provides information about the tally (GPIO) interface.
Topics

The Interface

GPIO Configuration Concepts
Configuring Outputs
Configuring Inputs
The Interface
The tally interface includes 8 optically isolated inputs and 4 solid-state relay outputs (also opti-
cally isolated). Tally devices you connect to inputs can trigger events — through the NV9640 —
in the router control system. The router control system can trigger events that — through the
relays in the NV9640 — switch your tally devices.
The DB25 connector, labeled "GPI Interface" at the rear of the NV9640 presents the tally signals.
There are 8 input signals and 4 pairs of output signals.
1 0
3 2 5 4
Fig. 6-1: GPI Interface

Input

The tally inputs expect contact closure to ground, through the ground pins on the connector, to
trigger a GPI input event.
Customer’s
Switch (or
Equivalent
Logic)
Fig. 6-2: GPI Input
When the input transitions off or transitions on, the NV9640 notifies the router control system,
which carries out the task defined for the input (if a task has been configured).
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
13
25
7 6
1 0
3 2
5 4
Inputs
+5V
+5V
C
Tally Input n
E
Optical
Isolation
Ground
1
14
– +
+ –
– +
+ –
7 6
0
1
2
3
Outputs
10K
to internal bus

GPIO

14
– +
+ –
– +
+ –
6
0
1
2
3
75

Advertisement

Table of Contents
loading

Table of Contents