Each 15-minute and 24-hour performance parameter
has a threshold as shown in the
screen,
Figure
Thresholds
Change Performance Threshold
automatically displays upon entering the threshold
number selection in
Figure
crossed, an event is logged in the Event Log History.
CIRCUIT ID: xxxxxxx
--------------------------------------------------------------------
1. CV-L
2. ES-L
3. SES-L
4. LOSS-L
--------------------------------------------------------------------
5. CV-P
6. ES-P
7. SES-P
8. UAS-P
17. Restore Default Thresholds
CIRCUIT ID: xxxxxxx
16
Performance
18. Thresholds can be set in
,
Figure
19, which
18. When a threshold is
Press ESC to return to previous menu
Performance Thresholds
15 Min
Line Related
= 387
= 025
= 004
= 004
15 Min
Path Related
= 382
= 025
= Disabled
= 010
Figure 18. Performance Thresholds Screen
Press ESC to return to previous menu
CV-L 15 Min Threshold = 387
D. Disable Threshold
Enter Value:
Figure 19. Change Performance Threshold Screen
The Line Related thresholds set the threshold for both
the network and customer line parameters for the near
end only. The Path Related thresholds set the thresholds
for the near and far path parameters for both network
and customer. All thresholds can be disabled or reset to
factory default.
24 Hr
9. CV-L
10. ES- L
11. SES-L
12. LOSS-L
24 Hr
13. CV-P
14. ES-P
15. SES-P
16. UAS-P
18. Disable All Thresholds
Selection:
01/01/01
13:04:03
= 00387
= 00025
= 00004
= 00004
= 00382
= 00025
= 00004
= 00010
01/01/01
13:04:03
61212075L2-5D