Operating and Installation - Battery Charger LAS 1218 BUS
1.3.2
Flat vehicle fuse
6
Faults
A fault in the power supply system is usually caused by a blown fuse.
Please contact our customer service address if you cannot rectify the fault
using the following table.
If this is not possible, e.g. if you are abroad, you can have the battery char-
ger repaired at a specialist workshop. In this case, you must ensure that the
warranty is not invalidated by incorrect repairs being carried out. Schaudt
GmbH will not accept any liability for damage resulting from such repairs.
Fault
Leisure area battery is not
charged during 230V
operation (battery voltage
operation (battery voltage
constantly below 13.3 V)
Leisure area battery is
overcharged during 230V
operation (battery voltage
rises to over 15V)
Starter battery is not
charged during 230V
operation (battery voltage
operation (battery voltage
constantly below 13.0 V)
1212V power supply in
1212V power supply in
the leisure area does not
the leisure area does not
work (when the battery
work (when the battery
charger is being used as
a power supply device)
The "Main / Full Charge"
indicator lamp does not
light up despite several
hours of charging
Date: 21.11.2018
Possible cause
No mains voltage
Battery charger is
defective
Battery charger fuse or
wiring is defective
Battery charger is
defective
No mains voltage
Battery charger is
defective
Defective fuse or cabling
Defective fuse or cabling
Battery charger is
defective
No mains voltage
Battery charger is
defective
Remedy
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Contact customer service
Have the fuse and cabling
checked
Contact customer service
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Contact customer service
Have the fuse and cabling
Have the fuse and cabling
checked
checked
Contact customer service
Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Contact customer service
8100532 BA / EN