Changing the battery
Indicator LEDs
Main / Full charge
Trickle charge
8100532 BA / EN
Operating and Installation - Battery Charger LAS 1218 BUS

Operation

Controls and indicator LEDs
The device has no controls which need to be used on a day-to-day basis.
The battery selector switches need only be set correctly on initial use and for
a change of battery.
DANGER!
Y
Risk of explosion!
An incorrect battery selector switch setting poses a risk of explosion
F
due to the formation of electrolytic gases.
ATTENTION!
Y
An incorrectly set battery selector switch will damage the leisure area
F
battery.
Disconnect the battery charger from the mains before moving the bat-
F
tery selector switch.
The LAS 1218 BUS charger may have to be reset when a battery type is
changed (see also Page 18).
 Batteries may only be replaced by qualified personnel.
 Follow the battery manufacturer's instructions.
 Charging unsuitable types of battery may damage them beyond repair.
It is possible to swap lead acid batteries with lead gel batteries.
Given the lack of ventilation options within the vehicle, changing from lead
gel to lead acid batteries is not possible without additional overhead.
Ask your dealer for advice.
The switching option provided by the battery selector switch ensures opti-
mum charging of the different battery types (lead-gel, lead-acid and AGM).
The indicator LEDs on the front of the battery charger show the current char-
ging phase.
This indicator LED lights up yellow in the "Main Charge" and "Full Charge"
phases.
This indicator LED lights up green in the "Trickle Charge" phase.
In supply mode, the two LEDs switch alternately every second.