Advertisement

E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de
8100532 BA / EN
Operating and Installation Instructions
LAS 1218 BUS Battery Charger
Contents
1
1.1
1.2
1.3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
2.1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2
2.3
2.4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.5
2.6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
2
2
3
5
7
8
8
8
9
18
20
21
22
Date: 21.11.2018

Advertisement

Table of Contents
loading

Summary of Contents for Schaudt LAS 1218 BUS

  • Page 1: Table Of Contents

    ..........E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt- -gmbh.de 8100532 BA / EN Date: 21.11.2018...
  • Page 2: Operating Instructions

    Operating and Installation - Battery Charger LAS 1218 BUS Operating instructions Safety information 1.1.1 Meaning of safety symbols DANGER! Failure to comply with this sign may result in danger to life or physical con- dition. WARNING! Failure to comply with this sign may result in injury.
  • Page 3: Application And Layout

    7 Installation feet  8 Mains cable with earthing type plug or WAGO -connector (optional) The LAS 1218 BUS battery charger is for charging suitable batteries during 230V operation or supplying 12V consumers without connected battery with power. Date: 21.11.2018...
  • Page 4 The LAS 1218 BUS battery charger is aligned perfectly to Schaudt bus sy-  stems, and a corresponding connection to the SDTBUS links the device into the system.
  • Page 5: Operation

    Disconnect the battery charger from the mains before moving the bat- tery selector switch. The LAS 1218 BUS charger may have to be reset when a battery type is changed (see also Page 18). Changing the battery  Batteries may only be replaced by qualified personnel.
  • Page 6 If this is not possible, e.g. if you are abroad, you can have the battery char- ger repaired at a specialist workshop. In this case, you must ensure that the warranty is not invalidated by incorrect repairs being carried out. Schaudt GmbH will not accept any liability for damage resulting from such repairs.
  • Page 7: Maintenance

    Operating and Installation - Battery Charger LAS 1218 BUS Fault Possible cause Remedy The ”Trickle Charge” System overloaded Switch off consumers indicator lamp does not indicator lamp does not Battery charger is Contact customer service light up despite several defective...
  • Page 8: Installation Instructions

    Operating and Installation - Battery Charger LAS 1218 BUS Installation instructions Introduction These installation instructions are aimed at trained personnel. They contain important information on the connection and safe operation of the device. The safety information provided must be observed.
  • Page 9: Electrical Connection

    ø4.5 Lumberg connector Fig. 1 Dimension diagram for LAS 1218 BUS battery charger (dimensions in mm) 2.2.2 Fuse holder For applications that require one or two additional fuses (see Section 2.3.1.3 for example), fuse holders from the connector set must be installed.
  • Page 10 Connection as for auxiliary charger to the electroblock Auxiliary charger The LAS 1218 BUS battery charger can also be used as an auxiliary charger for a Schaudt electroblock. Suitable for use here are all Schaudt electro- blocks that include the LAS charger module and have the 2-pin MN connec- tor (e.g.
  • Page 11 Connector cable, 1.7 m with MNL connector * Pos. 2 and 3 as an alternative depending on electroblock to be connected The connector cable (Pos. 2 or 3) is required to connect the LAS 1218 BUS battery charger to the electroblock.
  • Page 12  Route the cable through the vehicle to the LAS 1218 BUS battery char- ger.  Plug the TF 25 A battery temperature sensor into the LAS 1218 BUS bat- tery charger.  Secure the battery sensor cable at suitable places (particularly near the...
  • Page 13 Auxiliary charger The LAS 1218 BUS battery charger can also be used as an auxiliary charger in a Schaudt bus system. Up to two additional LAS 1218 BUS chargers can be connected to the EBL of the bus system.
  • Page 14  Route the cable through the vehicle to the LAS 1218 BUS battery char- ger.  Plug the TF 25 A battery temperature sensor into the LAS 1218 BUS bat- tery charger. Date: 21.11.2018 8100532 BA / EN...
  • Page 15 Flat vehicle fuse, 20A Flat vehicle fuse, 10 A The connector set (Pos. 2 to 6) is required to connect the LAS 1218 BUS battery charger to up to two batteries. The length of the line to the starter battery may not exceed 4 m (supply and return lines together) for a cable cross-section of 2.5mm...
  • Page 16 Operating and Installation - Battery Charger LAS 1218 BUS TF 25 A* Fig. 7 Connection diagram for LAS 1218 BUS battery charger - - to leisure and starter batte- ries Fuse F1 Fuse F2 Leisure area battery Starter battery TF 25 A battery temperature sensor is optional ...
  • Page 17  Route the cable through the vehicle to the LAS 1218 BUS battery char- ger.  Plug the TF 25 A battery temperature sensor into the LAS 1218 BUS bat- tery charger.  Secure the battery sensor cable at suitable places (particularly near the...
  • Page 18: Initial Use

    Operating and Installation - Battery Charger LAS 1218 BUS 2.3.2 Mains connection DANGER! 230V units carrying mains voltage. Risk of fatal injury due to electric shock or fire: Only carry out electrical work once the 230V supply has been discon- nected.
  • Page 19  Then re-check that the battery selector switch is in the correct position for the type of battery used. 2.4.3 Setting the address When a LAS 1218 BUS is used in Schaudt bus systems, every device con-  nected to the SDTBUS has an ”address”.
  • Page 20: Technical Details

    * Dependent on the battery type set charge Main charge Full charge Trickle charge Charge voltage Trickle charge voltage See table Time Fig. 9 Example of the charge voltage behaviour with the LAS 1218 BUS battery charger Date: 21.11.2018 8100532 BA / EN...
  • Page 21: Storage, Packaging And Transportation

    Operating and Installation - Battery Charger LAS 1218 BUS Battery type Charge Trickle charge At reference Time voltage voltage temperature phase Supply mode Fixed voltage 12.65V AGM2 14.75V 13.70V 22,5 C 4 hours Lead-gel / 14.45V 13.70V 22,5 C 12 hours...
  • Page 22: Appendix

    Operating and Installation - Battery Charger LAS 1218 BUS Appendix EC Declaration of Conformity Schaudt GmbH hereby confirms that the design of the LAS 1218 BUS bat- tery charger complies with the following relevant regulations: The original EC declaration of conformity is available for reference at any time.
  • Page 23 Operating and Installation - Battery Charger LAS 1218 BUS Fault report In the event of damage, please fill in the fault report and send it with the faulty device to the manufacturer. Device type: _______________________ Item no.: _______________________ Vehicle: Manufacturer: _______________________...
  • Page 24 Operating and Installation - Battery Charger LAS 1218 BUS (blank page) Date: 21.11.2018 8100532 BA / EN...

Table of Contents