TROUBLESHOOTING
Sym ptom s of Abnorm al
Operation
• Furnace fails to operate.
• Integrated control module LED
display provides
error code.
• Furnace fails to operate.
• Integrated control module LED
display provides
error code.
• Furnace fails to operate.
• Integrated control module LED
display provides
error code.
• Furnace fails to operate.
• Integrated control module LED
display provides
error
code.
• Furnace operates at
reduced performance or
operates on low stage w hen
high stage is expected.
• Integrated control module LED
display provides
error code.
Diagnostic /
Status LED
Fault Description
Code s
• Circulator blow er
motor senses
a loss of rotor control.
• Circulator blow er
motor senses high
current.
• Circulator blow er
motor fails to start 10
consecutive times.
Circulator blow er
motor shuts dow n for
over or under voltage
condition.
Circulator blow er
motor shuts dow n
due to over
temperature condition
on pow er module.
Circulator blow er
motor does not have
enough information to
operate properly.
Motor fails to start 40
consecutive times.
Airflow is low er than
demanded.
Possible Causes
• Abnormal motor loading,
• Check filters, filter grills/registers,
sudden change in speed or
duct system, and furnace air
torque, sudden blockage of
inlet/outlet for blockages.
furnace air inlet/outlet
• Obstruction in circular
• Check circular blow er for
blow housing.
obstructions. Remove and
• Seized circular blow er
repair/replace w heel/motor if
motor bearings
necessary
• Failed circular blow er
motor.
• High AC line voltage to
• Check pow er to furnace. Verify
furnace.
line voltage to furnace is w ithin the
• Low AC line voltace to
range specified on the furnace
furnace.
rating plate. See "III. Product
• High ambient temperatures.
description" and IV Location
Requirements and Considerations"
furnace installation requirements.
• Error w ith integrated
• Check integrated control module.
control module. Motor has a
Verify control is populated w ith
rotor condition.
correct shared data set. See data
errors above for details. Check for
locked rotor condition ( see error
code above for details).
• Blocked filters.
• Check filters for blockage. Clean
• Restrictive ductw ork.
filters or remove obstruction.
• Undersized ductw ork.
• Check ductw ork for blockage.
Remove obstruction. Verify all
registers are fully open.
• Verify ductw ork is appropriately
sized for system. Resize/replace
ductw ork if necessary.
Corrective Actions
• Turn pow er OFF prior to
repair
• Turn pow er OFF prior to
repair.
• Replace motor w ith correct
replacement part.
• Replace w heel w ith correct
replacement part.
• Turn pow er OFF prior to
repair.
• Replace motor w ith correct
replacement part.
• Use memory card for the
specifc model.
• Turn pow er off prior to
repair.
• Turn pow er OFF prior to
repair.
Notes & Cautions