Goodman ACVC8 CA Series AMVC8 CA Series Service And Troubleshooting page 46

Table of Contents

Advertisement

TROUBLESHOOTING
Name/Cloud/Phone App
Cool Trim Factor
Cool Airflow Profile
Cool On Delay
Cool Off Delay
Dehumidifcation Enable
Defrost Gas Heat Stage
Compressor Balance Points
HP Trim Factor
HP On Delay
HP Off Delay
HP Defrost Interval
Compressor Delay
History Fault and Clear
Name/Cloud/Phone App
Boost Mode
Boost Temp
Set Max Current
Vertical Rise
System Reset Menu
System Verification Test
Pump Down
Charge Mode
Cool-Trim Factor - High
Cool-Trim Factor - Intermediate
Cool-Trim Factor - Low
Cool Airflow Profile
Cool On Delay
Cool Off Delay
Dehum Enable
Cool Reset Menu
Cool Max RPS Range
Cool Max RPS Selection
Defrost Gas Heat Stage
Compressor Balance Points
Force Defrost
HP Trim Factor - High
HP Trim Factor - Intermediate
HP Trim Factor - Low
HP On Delay
HP Off Delay
HP Defrost Interval
HP Reset Menu
HP Max RPS Range
HP Max RPS Selection
History Fault and Clear
46
ClimateTalk Comm Outdoor 2-Stage AC/HP
7 Segment Display
User Modifiable Options
-10%, -8%,-6%, -4%, -2%, 0%, 2%, 4%, 6%, 8%,10%

A, B, C, D

5, 10, 20, 30
d
30, 60, 90, 120
d
ON, OFF
dE
1 or 2
d
Adjustable and defined in Shared Data

-10%, -8%,-6%, -4%, -2%, 0%, 2%, 4%, 6%, 8%,10%

5, 10, 15
d
30, 50, 70, 90
d
30, 60, 90, 120
dI
0, 5, 15, 30
dL
Yes or No.
L
ClimateTalk Comm Outdoor Inverter AC/HP
User Modifiable Options
7 Segment Display
On or Off

On(Always), 70F, 75F, 80F, 85F, 90F, 95F, 100F, 105F Provides the 9 temperature options for boot operation.

OFF, 40%, 50%, 60%, 70%, 80%, 90%

SL (Same Level), OL (Outdoor Lower), IL (Indoor

Lower)
Yes or No.

On or Off
On or Off
d
On or Off

-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15

-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15
I
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15
L
A, B, C, D

5, 10, 20, 30
d
30, 60, 90, 120
d
On or Off
dE
Yes or No.
L
01(58 to 62.5 RPS), 02(63 to 67.5 RPS), 03(68RPS),

04(68.5 to 73 RPS), 05(73.5 to 78 RPS)
10 RPS values from inverter

1 or 2
d
Adjustable and defined in Shared Data

On or Off
dd
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15

-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15
I
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15
L
5, 10, 20, 30
d
30, 60, 90, 120
d
Maximum amount of compressor runtime before
dI
defrost occurs.
Yes or No.

01(58 to 62.5 RPS), 02(63 to 67.5 RPS), 03(68RPS),

04(68.5 to 73 RPS), 05(73.5 to 78 RPS)
10 RPS values from inverter

Yes or No.
L
Comments
Trims the cooling airflow by the selected amount.
Select cooling airflow profiles.
Selects the cooling on delay.
Selects the cooling off delay.
Enables the dehum function for OD operation.
Selects the gas heat stage for defrost operation.
Selects the compressor balance point options for HP operation.
Trims the heating airflow by the selcted amount
Selects the HP heating on delay.
Selects the HP heating off delay.
Provides the defrost options for compressor heating operation.
Provides the compressor delay options for heating operation.
Views the comm outdoor history and clear the outdoor unit
history fault.
Comments
Provides the options for inverter boot operation.
Selects Max Current options
Selects the level of outdoor vas indoor equipment.
Reset all outdoor unit settings to factory default.
Runs System Verification Test after Installation.
Enters Pump Down mode.
Enters charge mode.
Trims the cooling airflow by the selected amount.
Trims the cooling airflow by the selected amount.
Trims the cooling airflow by the selected amount.
Select cooling airflow profiles.
Selects the cooling on delay.
Selects the cooling off delay.
Enables the dehum function for compressor operation.
Resets all cooling settings to factory default.
Selects the appropriate range for the installed system
configuration.
Selects the appropriate compressor RPS for the installed system
configuration.
Selects the gas heat stage for defrost operation.
Provides the compressor balance point options for HP operation.
Trims the heating airflow by the selected amount.
Trims the heating airflow by the selected amount.
Trims the heating airflow by the selected amount.
Selects the HP heating on delay.
Selects the HP heating on delay.
Provides the defrost options for compressor heating operation.
Resets all heating settings to factory default.
Selects the appropriate range for the installed system
configuration.
Selects the appropriate compressor RPS for the installed system
configuration.
Views the comm outdoor history and clear the outdoor unit
history fault.