Goodman ACVC8 CA Series AMVC8 CA Series Service And Troubleshooting page 45

Table of Contents

Advertisement

TROUBLESHOOTING
Name/Cloud/Phone App
Last 6 Faults
Learn Menu
Code Release No
Shared Data Revision
Reset To Factory Default
Constant Fan Speed
Gas Heating Airflow
Gas Heat Off Delay
Gas Heat On Delay
Gas Heat Trim Factor
Gas Heat Stage Multiplier
Gas Pressure Test
Function Enable/Disable
Backup Heat Balance Points
Comfort Setting
Hum On Enable
Ventilation On Time
DeHum Logic
Name/Cloud/Phone App
Tonnage
Cool Trim Factor
Cool Airflow Profile
Cool On Delay
Cool Off Delay
Cool Stage Multiplier
Defrost Gas Heat Stage
Compressor Balance Points
HP Trim Factor
HP On Delay
HP Off Delay
HP Stage Multiplier
Name/Cloud/Phone App
Cool Trim Factor
Cool Airflow Profile
Cool On Delay
7 Segment Display
User Modifiable Options
N/A
L
Yes or No.
L
N/A

N/A

Yes or No.

Adjustable between 25% to + 100% with 10% ingrements.
d
Default is 25%.
Adjustable between Min and Max. Min, Max, Step and

Default are defined in Shared Data.
Adjustable between 30 seconds to 180 seconds with 5
d
seconds increments. Default is 30 seconds.
Adjustable between 5 seconds to 30 seconds with 30
d
seconds increments. Default is 90 seconds.
Adjustable between -10% to +10% with 2% increments.

Default is 0%.
Adjustable between Min and Max. Min, Max, Step and

Default are defined in Shared Data.
Yes or No.

d
Adjustable between Min and Max. Min, Max, Step and

Default are defined in Shared Data.
First 5 option values are defined in Shared Data. The 6th
option shall be hard-coded in the firmware with other 5

settings. The default value is Option 1.
1 ~ 16 options and the default option is 15.
d
Adjustable between 0 ~ 60 minutes. The default is 0

minute Off).
Hi and Lo. The default is Lo.
dL
Outdoor AC/HP, Single-Stage AC/HP
7 Segment Display
User Modifiable Options
Adjustable between 1 to 6 ton with 0.1 increments.

Default is 3 ton.
Adjustable between -10% to +10% with 2% increments.

Default is 0%.
A(1), B(2), C(3), D(4 or 5)

Adjustable between 5 to 30 seconds with 5 seconds
d
increments. Default is 5 seconds.
Adjustable between 30 to 120 seconds with 30 seconds
d
increments. Default is 60 seconds.
Adjustable between 60% to + 100% with 1% increments.

Default is 70%.
1 or 2
d
Adjustable and defined in Shared Data

Adjustable between -10% to +10% with 2% increments.

Default is 0%.
Adjustable between 5 to 30 seconds with 5 seconds
d
increments. Default is 5 seconds.
Adjustable between 30 to 120 seconds with 30 seconds

increments. Default is 60 seconds.
Adjustable between 70% to 100% with 5% increments.

Default is 70%.
ClimateTalk Comm Outdoor 2-Stage AC/HP
User Modifiable Options
7 Segment Display
-10%, -8%,-6%, -4%, -2%, 0%, 2%, 4%, 6%, 8%,10%

A, B, C, D

5, 10, 20, 30
d
Furnace
Views the control last 6 history faults.
Resets communication network.
Views the control firmware revision number and Shared Data number.
Views the control Shared Data revision number and shared data upload.
Reset the furnace setting to factory defaults.
Select the indoor blower airflow at constant fan mode.
Select the indoor blower airflow multiplier for gas heat operation.
Selects the indoor blower heat off delay.
Selects the indoor blower heat off delay.
Trims the heating airflow by the selected amount.
Selects gas heat stage multiplier
Checks gas valve pressure at 100% firing rate.
Not implemented in the initial
This menu only shows up when a communicating Heat Pump is detected.
Provides the 6 comfort setting options for the furnace staging algorithm
operation, only shows up when ClimateTalk or DataAC T-Stat is not
connected.
Provides the 16 humidifier enabling options in different operation
modes.
Adjusts the ventilation on time and turn it on/off.
Provides the DeHum logic input level for DeHum operation. Only applies
when the legacy 24VAC input is active.
Only visible when communicating outdoor unit is not detected.
Trims the cooling airflow by the selected amount.
Select cooling airflow profiles.
Selects the cooling on delay.
Selects the cooling off delay.
Selects stage multiplier for 2-stage OD unit.
Selects the gas heat stage for defrost operation.
Provides the compressor balance point options for HP operation.
Trims the heating airflow by the selected amount.
Selects the HP heating on delay.
Selects the HP heating off delay
Select stage multiplier for 2-stage OD unit.
Trims the cooling airflow by the selected amount.
Select cooling airflow profiles.
Selects the cooling on delay.
Comments
Comments
Comments
45