Omron Sti G9SX-LM224-F10 Series User Manual page 3

Low speed monitoring unit
Table of Contents

Advertisement

1
Appearance and Explanation of Each Parts
Type G9SX-LM224-F10-
Feedback/Reset input
Enable input ch1
Mode selector input
Safety Input ch1
Safety Input ch2
Enable Input ch2
Auxiliary Error output
Auxiliary Monitor output
Auxiliary Monitor output
Safety solid-state outputs
*Note: When you connect the Expansion Unit, please remove the termination connector from the receptacle on the G9SX-LM and insert the Expansion Unit cable connector
into the receptacle, and insert the terminating connector into the receptacle on the Expansion Unit at the very end (rightmost).
A maximum of five Expansion Units can be connected to one G9SX-LM. This may be a combination of the G9SX-EX instantaneous Expansion Unit and the G9SX-EX-T
OFF-delayed Expansion Unit. When the G9SX-EX-T OFF-delayed Expansion Unit is connected, it will operate in the same way as the G9SX-EX instantaneous Expansion
Unit.
Settings indication
(at power on)
Settings for G9SX-LM can be checked by indicators for approx. 3 seconds after power on.
During the settings indication term, ERR indicator will light up,
however the auxiliary error output will remain off.
Indicator
Items
Setting
position
Cross fault
T1
Y1 terminal
detection
(Enable Input )
Cross fault
Y2 terminal
T6
detection
(Safety Input )
T32 or T33
Reset
FB
terminal
Logical AND
Logical AND
connection
AND
connection
input
preset switch
LED Indicators
LED
Color
Name
Function
Green
Power Supply
- Lights up while power is supplied.
PWR
Indicator
Red
- Lights up or blinks corresponding to the occurring an error (*1)
ERR
Error Indicator
T1
Orange
Enable input
- Lights up while high signal is input to T12
- Blinks when an error relating to Enable input ch1 occurs. (*1)
ch1 Indicator
Enable input
T2
Orange
- Lights up while high signal is input to T22
ch2 Indicator
- Blinks when an error relating to Enable input ch2 occurs. (*1)
T6
Orange
Safety input
- Lights up while high signal is input to T62
ch1 Indicator
- Blinks when an error relating to Safety input ch1 occurs. (*1)
Safety input
T7
Orange
- Lights up while high signal is input to T72
ch2 Indicator
- Blinks when an error relating to Safety input ch2 occurs. (*1)
AND
Orange
Logical AND
- Lights up while high signal is input to T41.
- Blinks when an error relating to Logical AND connection Input
input Indicator
occurs. (*1)
FB
Orange
Feedback/Reset
- Lights up in the following cases:
-- With automatic reset while high signal is input to T33
input Indicator
-- With manual reset while high signal is input to T32.
- Blinks when an error relating to Feedback/Reset input occurs. (*1)
Orange
Safety output
- Lights up while Safety solid-state outputs (S14, S24)
EI
indicator
are in ON-state.
- Blinks when an error relating to Safety solid-state output occurs. (*1)
ES
Orange
Safety speed
- Lights up while Safety speed detection outputs (ES1,
detection output
ES2) are in ON-state.
- Blinks when an error relating to Safety speed detection
Indicator
outputs occurs.(*1)
Operation
- Lights up while the Maintenance mode is in ON-state.
MOD Orange
mode
- Blinks when an error relating to m ode selector input occurs.(*1)
Indicator
- Blinks when Rotation detection input signals (D12 and
Rotation
DS
Orange
D22) indicate a low-speed condition (lower than the
detection
Low-speed monitoring frequency)
input
- Light up when Rotation detection input signals (D12
and D22) indicate a standstill condition (2Hz or less)
Indicator
- Blinks when an error related to Rotation detection inputs
occurs.(*1)
*1. See 7 Fault Detection for details.
T31
T32
T33
M1
D12
D22
D11
D21
T11
T12
T61
T62
M2
Y1
Y2
A1
G9SX-LM224-F10
24VDC
AND
PWB
FB
T1
T2
MOD
T6
T7
DS
EI
ES
4.7 5.3
3.6 4.2
6.0
3.2
6.6
ERR
3.0
7.3
2.8
8.4
2.4
9.3
2.2 2
10
No.
SPD
T21
T22
T71
T72
T41
T42
L1
A2
X1
X2
X3
X4
S14
S24
ES1
ES2
indicator
Setting
status
lit
detection
Y1 = open
not lit
non-detection
Y1 = 24VDC
lit
detection
Y2 = open
not lit
non-detection
Y2 = 24VDC
lit
manual reset
T33 = 24VDC
not lit
auto reset
T32 = 24VDC
lit
enable Logical AND input
'AND'
not lit
disable Logical AND input
'OFF'
Sensor power supply
Rotation detection input
Power Supply(+)
Cross fault detection input
Mode selector input
Termination
Connector
Low-speed monitoring
frequency preset switch
Logical AND
connection input
Logical AND
connection output
Power Supply(-)
Safety speed detection output
Logical AND connection preset switch
Preset Switches
Change the value of the preset switches only when G9SX-LM is disconnected from
power supply.
The states of the preset switches come into effect when the power supply to G9SX-LM turns on.
Setting
Name
status
Logical AND
Connection
Preset Switch
Low speed
monitoring
Preset switch
*2. When operating G9SX-LM using Logical AND Connection function, be sure to set
the preset switch to AND (valid) position for the units which the logical input signal is
input to. When the switch is set to OFF (invalid) position, it is detected as a fault.
*3. Set both of the two Low speed monitoring Preset Switches, one each on the front and
back, to the same value.
*4. See illustration to the right for setting position of Low speed monitoring Preset switch.
Make sure that the direction of cutting edge of preset switch is correctly pointed to the
Low speed monitoring frequency value which must be set.
3.6
3.2
3
2.8
2.4
2.2
ex.1)Low speed monitoring frequency 2Hz setting ex.2)Low speed monitoring frequency 4.2Hz setting
- 3 -
3.6
6
3.2
6.6
3.0
7.3
2.8
8.4
2.4
9.3
2.2
10
2
SPD
AND
OFF
T41/T42
Function
State/Value (position of switch)
Sets Logical AND
OFF (Invalid: default setting)/
Connection Inputs to
AND (valid)
valid or invalid. (*2)
Low speed monitoring
2 (default setting value)
frequency preset.(*3)
/2.2/2.4/2.8/3.0/3.2/3.6/4.2/4.7/5.3
/6.0/6.6/7.3/8.4/9.3/10 (Hz) (*4)
4.7
4.2
5.3
6
6.6
7.3
8.4
9.3
10
2
SPD
cutting edge
4.7
4.2
5.3
3.6
6
3.2
6.6
3
7.3
2.8
8.4
9.3
2.4
2.2
10
2
SPD

Advertisement

Table of Contents
loading

Table of Contents