Constant Voltage Mode (Cv) - Et system ELP/DCH Series User Manual

Programmable dc electronic load
Table of Contents

Advertisement

ET System electronic GmbH

3.1.2 Constant Voltage Mode (CV)

In constant voltage mode, the E-load will cause a constant voltage to appear at its
terminals.
Figure 3.2 CV mode
In CV mode, the E- load provides two methods to modify the constant voltage value.
1) In CV mode, use the numeric keys to input the voltage value, press the key
to
confirm the setup constant voltage value; press the button
to ON/OFF the loading
test.
2) Press the key
to move the cursor position and press the key
to adjust the value
at the corresponding position.
21

Advertisement

Table of Contents
loading

Table of Contents