Electrolux EKC 603505 Instruction Booklet page 34

Ceramic free-standing electric cooker
Table of Contents

Advertisement

Available languages

Available languages

34 electrolux
Suitable power supply cables are the
following types, considering the
respective necessary section of cable.
H07 RN-F
H05 RN-F
H05 RR-F
H05 VV-F
H05 V2V2-F (T90)
The replacement of electric
cable must be carried out
exclusively by the service
force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
Connecting the terminal board
The appliance incorporates an eas-
ily accessible 6-pole terminal board
whose jumpers (bridges) are already
pre-set for operation on 400 V three-
phase with neutral wire. In case where
different mains voltage is present, the
jumpers on the terminal board must be
arranged as shown in the diagram.
The ground cable must be con-
nected to terminal
After connecting the supply cable to
the terminal board, secure it with a junc-
tion clamp.
.
1 2 3 4 5
230V 3~
L1
L2
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1 L2
1 2 3 4 5
400V 3N~
L1 L2 L3 N
Section
of cable
(min.)
L3 PE
4 x 1.5 mm
Section
of cable
(min.)
3 x 2.5 mm
N
PE
Section
of cable
(min.)
4 x 2.5 mm
N
PE
Section
of cable
(min.)
5 x 1.5 mm
PE
2
2
2
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekc 603505 x

Table of Contents