Setup; Power; Mounting - Chauvet LEDrain 64 User Manual

Chauvet ledrain 64 light fixtures: user manual
Hide thumbs Also See for LEDrain 64:
Table of Contents

Advertisement

S
ETUP

Power

This fixture has an auto-switching power supply that can accommodate a wide range of input voltages. The
only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is
within the range of accepted voltages. This fixture will accommodate between 100V and 240V AC. To
determine the power requirements for a particular fixture, see the label affixed to the back plate of the
fixture or refer to the fixture's specifications chart.
• A fixture's listed current rating is its average current draw under normal conditions.
• All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%
to 100% switch.
• All fixtures must be connected to circuits with a suitable Earth Ground.
Pow er C able C onf igur at io n
C
ABLE
B
ROWN
B
LUE
Y
ELLOW

Mounting

O r ie ntat i on
This fixture may be mounted in any position provided there is
adequate room for ventilation.
R ig g in g
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted.
1. Align the clamp screw with the center hole on the yoke and tighten.
2. Verify the structure can hold 10 times the weight of all to-be installed fixtures.
3. Adjust the angle on the yoke arm as necessary.
LEDrain™64 User Manual
P
I
IN
NTERNATIONAL
Live
Neutral
/G
Earth
EG (Ground)
REEN
L
N
6
Introduction
Hanging Clamp
(sold separately)
2007-11-28/09:55