Removing The Box Fan And Blow Fan - LG LSE4617ST Service Manual

30” electric range
Hide thumbs Also See for LSE4617ST:
Table of Contents

Advertisement

REMOVING THE BOX FAN AND BLOW FAN

WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
electric range handling the sheet
metal part.
- Sharp edge may be present and you can cut
yourself.
1. Turn off the electrical supply going to the range.
2. Pull the range away from the wall so that you can
access the rear panel.
3. Pull the controller from the range.(See page 3-4)
4. Pull the Cooktop from the range(See page 3-7)
5. Remove the ceramic glass cooktop(See page
3-8)
6. Remove the Working coil plate(See page 3-9,10)
7. To remove the BOX FAN
a) Unplug the 2 BOX FAN connectors from the
Cooktop main PCB.
COMPONENT ACCESS
b) Change the position in reverse. After that,
remove the 4 Box fan screws.
8. To remove the BLOW FAN
a) Unplug the 1 BLOW FAN connector from the
Inverter PCB.
(Same as Right Side)
b) Change the position in reverse. After that,
remove the 4 Blow fan screws.
3-15