Honeywell S8600 Manual page 8

Intermittent pilot modules
Table of Contents

Advertisement

PILOT
COM
1ST
2ND
OPERATOR OPERATOR
DUAL VALVE COMBINATION
GAS CONTROL
Q345, Q346,
Q348, Q362, Q381
PILOT BURNER/
IGNITER-SENSOR
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
2 ALTERNATE LIMIT CONTROLLER LOCATION.
3 MAXIMUM CABLE LENGTH 3 ft [0.9 m].
4 CONTROLS IN 24V CIRCUIT MUST NOT BE IN GROUND LEG TO TRANSFORMER.
5 FOR MODULE WITH TH-W TERMINAL AND VENT DAMPER PLUG, CONNECT THERMOSTAT TO TH-W.
LEAVE 24V OPEN. DO NOT REMOVE VENT DAMPER PLUG.
6 COLORS REFER TO WIRE HARNESS, IF USED.
M1180C
Fig. 7—S8600F,H,M; S8610F,H; S8660D; S8670D in a heating system with an atmospheric burner and a
D80B vent damper.
44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170.
Website:
Line ID: @add11 e-mail: add028883472@gmail.com
S8600F,H,M; S8610F,H; S8660D; S8670D
GND
MV MV/PV PV (BURNER)
MAIN
VALVE
PILOT
BURNER
GROUND
PILOT GAS
SUPPLY
TRANSFORMER
L2
L1
(HOT)
LIMIT
2
CONTROLLER
1
8
https://www.add-furnace.com/
5 VENT
24V
TH-W
DAMPER
PLUG (OPT)
GND 24V (OPT)
5
D80B
END SWITCH
N.O. N.C.
1K2
1K
1K3
1
2
6
4
THERMOSTAT
OR
CONTROLLER
โทร: 02-888-3472
SPARK
3
1K1
R
3
4
5
LIMIT
CONTROLLER

Hide quick links: