POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
2
ALTERNATE LIMIT CONTROLLER LOCATION.
3 MAXIMUM CABLE LENGTH 3 FEET [0.9 METERS].
4 CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
5 REMOVE PLUG ONLY IF USING VENT DAMPER.
M1185D
Fig. 4—S8600A,B; S8610A,B with vent damper plug in an atmospheric burner heating system with a D80D vent
damper.
S8600F,H,M; S8610F,H; S8660D; S8670D
MV MV/PV PV (BURNER)
MAIN
VALVE
PILOT
COM
1ST
2ND
OPERATOR OPERATOR
DUAL VALVE COMBINATION
GAS CONTROL
Q345, Q346,
Q348, Q362, Q381
PILOT BURNER/
IGNITER-SENSOR
Fig. 5—S8600F,H,M; S8610F,H; S8660D; S8670D connections in a heating system with power-assisted
combustion.
S8600A,B; S8610A,B
PILOT
COM
1ST
2ND
OPERATOR OPERATOR
DUAL VALVE COMBINATION
GAS CONTROL
IGNITER
5 VENT
GND
24V
TH-W
GND 24V (OPT)
5
AIR
PROVING
SWITCH
COMBUSTION
AIR BLOWER
RELAY
L1
L2
(HOT)
COMBUSTION
PILOT
1 AIR BLOWER
BURNER
MOTOR
GROUND
PILOT GAS
SUPPLY
44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170.
Website:
https://www.add-furnace.com/
Line ID: @add11 e-mail: add028883472@gmail.com
GND
24V
GND 24V TH-W
MV MV/PV PV (BURNER)
MAIN
VALVE
SENSOR
GROUND
PILOT GAS
SUPPLY
DAMPER
PLUG (OPT)
SPARK
3
THERMOSTAT
2
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
2 ALTERNATE LIMIT CONTROLLER LOCATION.
4
3
4
LIMIT
CONTROLLER
5 FOR MODULE WITH TH-W TERMINAL AND VENT
L2 L1
(HOT)
1
6
โทร: 02-888-3472
VENT
DAMPER
PLUG
5
SENSE
197516A
WIRING
HARNESS
THERMOSTAT
2
D80D VENT DAMPER
1
L2
4
L1
(HOT)
LIMIT
CONTROLLER
AND OVERLOAD PROTECTION AS REQUIRED.
MAXIMUM CABLE LENGTH 3 ft [0.9 m].
CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
DAMPER PLUG, CONNECT THERMOSTAT TO TH-W.
LEAVE 24V OPEN. DO NOT REMOVE VENT DAMPER PLUG.
SPARK
3
M1177C