• DISCONNECT POWER BEFORE
SERVICING.
• "DO NOT TOUCH" ELECTRICAL
OR UNGROUNDED METAL
PARTS WHILE SERVICING WITH
POWER CONNECTED.
To check resistance:
1) Be sure hood is powered off.
2) Disconnect each motor connector.
3) Use a multimeter to measure values of
each connector.
To Power
Board
BLACK
Note: See resistance
values above.
BROWN
Tolerance +/- 5% [20˚C-68F]
BLUE
Pub. No. 31-14901
• T E C H N I C A L D A T A S H E E T •
POWER MUST BE DISCONNECTED BEFORE SERVICING THE APPLIANCE
CONTROL PCB
CN3
CN4
CN5
BROWN
RED
BLUE
ORANGE
BLACK
CONNECTOR 2
CONNECTOR 1
From Motor
ORANGE
RED
M
M
WHITE
YELLOW/GREEN
YELLOW/GREEN
WARNING
SCHEMATIC DIAGRAM
CN7
CN11
CN3
LINE
BLACK
NEUT.
WHITE
GND
YELLOW/GREEN
CN1 CN6
WHITE
WHITE
BLACK
ORANGE
BLUE
RED
BROWN
CN1
RED
BROWN
WHITE
25 uF
25 uF
MOTOR
CAP.
SPEED
WINDINGS
Vin ( 120V-60Hz )
low
red-black
red-brown
medium
red-black
red-orange
red-white
high
blue-white
boost
red-black
white-black
BROWN
CN4
BLUE
BROWN
CN5
BLUE
RED
CN7
CN11
USER INTERFACE
ASSEMBLY
RESISTANCE
0
( S.C )
7,6
6,5
6,5
4 LAMPS 120V AC
25W
FILTER
MICRO-
SWITCH

Advertisement

loading
Need help?

Need help?

Do you have a question about the ZV1050 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Monogram ZV1050

  • Page 1 • T E C H N I C A L D A T A S H E E T • WARNING • DISCONNECT POWER BEFORE POWER MUST BE DISCONNECTED BEFORE SERVICING THE APPLIANCE SERVICING. • “DO NOT TOUCH” ELECTRICAL OR UNGROUNDED METAL SCHEMATIC DIAGRAM CONTROL PCB PARTS WHILE SERVICING WITH...
  • Page 2 • T E C H N I C A L D A T A S H E E T • MONOGRAM ZV1050 ISLAND HOOD REMOVE FILTERS: 6) HALOGEN LAMPS Spring clips For access to lighting and wiring. The four halogen bulbs are the push-in type rated IMPORTANT SAFETY NOTICE at 120V, 25 watts, T4, clear, 9mm bi-pin.