The EcoGun Cleaner M is an equipment used for ,automatic washing, of conventional and Electrostatic manual spray guns When used with a EcoDose 2K system or similar , the EcoGun Cleaner M operates with a controller to automatically flush manual guns into an enclosed waste container.
2.3 Determination of the Ex Zones and typical installation Typical Installation of the EcoGun Cleaner M in EcoDose 2K System , or similar. electrical panel EcoDose 2K Flow meter Valves colour change Spray gun EcoGun Cleaner M box collecting dirty solvent A T T E N T I O N In normal operation, an explosive atmosphere is only present inside the spray booth.
Addition to respect the safety instructions in this manual, for the transport operations - installation - normal functioning - maintenance , also refer to the instructions contained in the manuals of the equipment connected to the EcoGun Cleaner M . For example: ·...
- are informed about the possible dangers - know the valid safety regulations. The installation, maintenance and repair of the EcoGun Cleaner M may only be carried out by experienced personnel [3]. An adequate advanced training or qualification of the personnel is to be carried out regularly.
3.3 Basic Information on our Safety Notes A T T E N T I O N The general dangers in the installation of EcoGun Cleaner M are not expressly referred to in this manual. The personnel must be informed by the customer and correspondingly trained concerning these dangers.
C A U T I O N Danger of minor injuries 4.1 Transport The EcoGun Cleaner M It is packed and shipped in a cardboard box 4.2 Storage Environmental conditions in the storage place: - Temperature: 5 °C - 40 °C - Humidity: 35 % –...
To avoid hazardous concentrations of flammable or toxic fumes, install the EcoGun Cleaner M in a properly ventilated spray booth. Locate the EcoGun Cleaner M in an area easily accessible to the operator and away from the spray or application point.
The operator places the spray gun in the EcoGun Cleaner M and closes the cover The interlock systems of the EcoGun Cleaner M intercept the atomizing air to the gun to prevent atomization of the solvent when you start washing and...
W A R N I N G Toxic fumes hazard If is not possible connect the EcoGun Cleaner M directly to the tank of the spray booth, to reduce the risk of splashes, you need to connect a pipe (plastic or metal connected to ground ) of at least 0.6 meters.
To reduce the risk of fire, explosion or electric shock, the system and the operators must be properly grounded. 6.3.1 EcoGun Cleaner M Must be connected to the network equipotential earth, the EcoGun Cleaner M using the dedicated terminal 6.3.2...
C A U T I O N Max air pressure.: 0,7 MPa (7bar). Use the quick couplings for hose Elastolan 2,7x4 on the bottom of the EcoGun Cleaner M A T T E N T I O N See pneumatic scheme 0300026.PI.GE.01 rev. 01 chapter 10.
Page 27
A T T E N T I O N Normally, the regulation of the correct positioning of the gun, is carried out by the manufacturer during the functional testing dell' EcoGun Cleaner M. Otherwise follow this procedure to ensure that the gun is operated correctly...
Wear personal protection outfit. Always wear the following protection outfit during the assembly. 7.1 starting The EcoGun Cleaner M has been tested by the manufacturer but is essential before the first start-up: · ensure that you have complied with all the steps described in chapter 6 ·...
Page 32
Directions and following images were made hypothesizing the connection with a EcoDose2K STEP 1 STEP 2 Put the gun in the EcoGun Cleaner M close the cover STEP 3 Turn on the cleaning operation from the operator panel of EcoDose 2K...
11 Gun is not in EcoGun Place the gun in the EcoGun Cleaner M Cleaner M EcoGun Cleaner M fails to purge after the pot life time ends. Gun switch is not Test the switch. Replace it if it...
Need help?
Do you have a question about the EcoGun Cleaner M and is the answer not in the manual?
Questions and answers