2.3.3
WX3 = Status
Codes
The status-code word continuously reports status and error information to
the PLC. All error bits are checked prior to starting a cycle. See Table 2-3.
For example, WX3 = binary value 1100 0000 0000 0000 indicates that the
module is in the run mode and is running a profile. The I/O mapping and
scaling feature allows a larger selection of devices to be interfaced to a
module. Download table locations 257 through 283 specify required
parameters. WX3 bit 9 has been defined to denote if any of these
parameters are invalid. If bits 1 through 8 of WY8 are set, and any entries
are invalid, the module exits RUN mode.
(16-Bit Word)
Bit 1(MSB)
Bit 16(LSB)
[.... .... .... ...1]
[.... .... .... ..1.]
[.... .... .... .1..]
[.... .... .... 1...]
[.... .... ...1 ....]
[.... .... ..1. ....]
[.... .... .1.. ....]
[.... xxxx 1... ....]
[..00 .... .... ....]
[..01 .... .... ....]
[..10 .... .... ....]
[..11 .... .... ....]
[.1.. .... .... ....]
[1... .... .... ....]
* Data is out of bounds or data is out of sequence (for active profiles only).
NOTE: To clear any of the above errors, force the first 5 bits of word WY8 to
zero, then enter a new run command.
Table 2-3 WX3 = Status Codes
Cycle Complete Code
Illegal V-memory pointer in WY5 or WY6
(pointers are out of bounds)
Illegal V-memory pointer in WY5 or WY6
(pointers overlap)
Clamp closure profile data error *
Injection profile data error *
Pack and hold profile data error *
Plasticate profile data error *
Clamp opening profile data error *
Error bit for mapping and scaling
Output configuration 1
Output configuration 2
Output configuration 3
Reserved
Defaults to 1 (reserved)
Profile execution in progress
Software Interface
2-7