2.3

PLC Input Words: Module Data

2.3.1
WX1 = Module
Cycle Status
The module-cycle-status word continuously reports both the profile and the
step that the module is currently executing to the PLC. See Table 2-1. For
example, WX1 = 305 means the module is currently executing Step 5 of
Pack and Hold.
Table 2-1 WX1 = Module Cycle Status
Function Code (integer)
0
101
110
111
201
210
211
301
310
311
401
410
411
501
510
511
*10101
*11010
*
Overlapping cycles on

PLC

Function
Module initialized or not in run mode
Step 1
Clamp close profile
Step 10
Clamp close profile
Clamp closure complete
Step 1
Injection profile
Step 10
Injection profile
Injection complete
Step 1
Pack and hold profile
Step 10
Pack and hold profile
Pack and hold complete
Step 1
Plasticate profile
Step 10
Plasticate profile
Plasticate complete
Step 1
Clamp open profile
Step 10
Clamp open profile
Clamp open complete
Plasticate and clamp open
Step 1
profiles (overlapping cycles on)
Plasticate and clamp open
Step 10
profiles (overlapping cycles on)
Clamp open profile step
Plasticate profile step
Software Interface
2-5