Startup Values and Examples (continued)
3-18
Installation and Startup
Table 3-5 Download Table (continued)
Location
Value
Clamp Open Profile
V177
5000
V178
300
V179
V180
V181
V182
V183
V184
V185
V186
V187
V188
V189
V190
V191
1600
V192
2500
V193–V200
V201
8000
V202
4000
V203–V210
V211
8000
V212
4000
V213–V220
Note: The two steps shown for each profile can be from Step 1 to 10.
Description of Function
Sets module scan to 5 ms during open
Sets opening time to 3 seconds maximum
0
Not used
0
Not used
0
Not used
30
Velocity scaling factor = 30 counts/ms
50
Velocity loop gain
0
Velocity loop rate
0
Velocity loop reset
0
Velocity/pressure operation = default
50
Pressure loop gain
0
Pressure loop rate
0
Pressure loop reset
0
Velocity/pressure data acquisition = default
Any number approximately half open
Any number fully open position
0
Other steps to be filled in later
Velocity = 1/4 speed
Velocity = 1/8 speed
0
Pressure = 1/4 of maximum
Pressure = 1/8 of maximum
0
Other steps to be filled in later